bg

Siemens Hipath-3700. SMDR/CDR data format and connection settings


This data is being extracted with help of the "Advanced PBX Data Logger" software only. It may not applicable for other software titles.

General

This information is applicable for Siemens Hipath 3000, Siemens Hipath 3350, Siemens Hipath 3500 and Siemens Hipath 3750.

RS232 (V.24). Connection parameters

Default parameters for serial communication: 9600-8-N-1 with hardware flow control.

Configure your PBX using the programming software, like HiPath 3000 Manager.

Go to: System status – Call charges – Output format

V.24 settings

Pinout and wiring

PC (9 pin) PBX (9 pin)
1 1
2 3
3 2
4 6
5 5
6 4
7 8
8 7
9 9

LAN. Connection parameters

Configure your PBX using the programming software, like HiPath 3000 Manager.

Go to: System status – Call charges – Output format (fig. 2)

SMDR. Output Format

Output format: LAN-TCP-Client
MRAT: none

Change LAN settings (fig. 3):
IP address: 192.168.1.1 (IP address of your computer with Advanced PBX Data Logger)
TCP port: 1080 (recommended)

LAN settings

Advanced PBX Data Logger

Configure our software to the TCP server mode (fig. 4). Please, note that you should specify the same IP address and port as in the LAN settings. 0.0.0.0 means that the program will listen on all available network interfaces.

TCP Server Mode

Date format

Verify that the date format in the parser and in your PBX are identical.

Parser for your PBX

Date Format

Configuring a COM port

The COM port number should match the number in your system. You can check the correct port number in Devices Manager → Ports.

1. Add a new configuration with the RS232 data source (if you didn't it before).

RS232 Interface

2. Select the COM port and configure the communication settings for your PBX corresponding to your PBX settings.

RS232 or COM port settings for (none)
Port flow control settings (none)

Data items

DescriptionData typeColumn name
Call timedatetimeCALL_TIME
COstringTRUNK
ExternalstringEXT
RingdatetimeRING
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
Call typestringCALL_TYPE
DirectionstringDIRECTION
Caller phonestringCALLER_PHONE
PhonestringDIALED_PHONE
CostfloatCOST
Account codestringACC

Interested in reports for PBX usage?

We offer the PBX Reports utility, which includes various manual, scheduled, and email reports, a built-in web server, and other features. You can implement your call accounting system for Siemens Hipath-3700. Check our PBX Reports utility.

Want PBX call logs in a database?

This is the standard feature: the logger captures and exports SMDR or CDR data in real-time to your database. Check our article about call logging to a database.

Siemens Hipath-3700 related connection settings

Siemens Hipath-3550
Siemens Hipath-35xx (CSV)
Siemens Hipath-37xx (CSV)
Siemens Hipath-37xx (Delimited by Pipe)
Siemens Hipath-3800

Quick jump to the connection settings for other PBXs or connection formats ↴

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.