DNC and CNC setting for Fanuc O
These settings are for the DNC Precision software only. They may not work with other software.
Fanuc O-T - Machine parameters
Set the following parameters on the machine
Press the [Parameters] button for parameters settings |
Press the [PAGE DOWN] button and select the 'Settings 2' submode |
Set the 'MODE SELECT' switch to 'MDI' |
Set the 'NO PWE' parameter to 1 and press the 'Input' button. After changing parameters below, change this value to 0 again |
Select the 'Settings 2' submode |
Set I/O = 1 |
With help of 'PAGE DOWN' and 'PAGE UP' buttons change bits in the following parameters. Please, don't change bits that didn't print in the table below |
#002 (stop bit and data format) |
bit 0 | 0 (1 stop bit) |
bit 2 | 0 (RS232) |
bit 3 | 1 (ASCII) |
#0552 (baud rate). Set this parameter = 9 |
Baud | Parameter value |
2400 | 9 |
4800 | 10 |
9600 | 11 |
19200 | 12 |
#0038 (IO device) |
bit 1 | 0 |
bit 2 | 1 |
bit 4 | 0 |
bit 5 | 1 |
bit 6 | 0 |
bit 7 | 1 |
#0051 (Parity) |
bit 1 | 1 (Yes) |
#0055 (Additional parameters) |
bit 0 | 1 (ASCII) |
bit 1 | 0 (CR) |
bit 2 | 0 (Protocol A) |
bit 3 | 0 (RS232) |
Set the following parameters on the PC
Serial port tab
Machine name | Fanuc O-T |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A#0D#0D
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No |
Fanuc O-TC - NC settings
Set the following parameters on the machine
Press the [Parameters] button for parameters settings |
Press the [PAGE DOWN] button and select the 'Settings 2' submode |
Set the 'MODE SELECT' switch to 'MDI' |
Set the 'NO PWE' parameter to 1 and press the 'Input' button. After changing parameters below, change this value to 0 again |
Select the 'Settings 2' submode |
Set I/O = 1 |
With help of 'PAGE DOWN' and 'PAGE UP' buttons change bits in the following parameters. Please, don't change bits that didn't print in the table below |
#002 (stop bit and data format) |
bit 0 | 0 (1 stop bit) |
bit 2 | 0 (RS232) |
bit 3 | 1 (ASCII) |
#0552 (baud rate). Set this parameter = 9 |
Baud | Parameter value |
2400 | 9 |
4800 | 10 |
9600 | 11 |
19200 | 12 |
#0038 (IO device) |
bit 1 | 0 |
bit 2 | 1 |
bit 4 | 0 |
bit 5 | 1 |
bit 6 | 0 |
bit 7 | 1 |
#0051 (Parity) |
bit 1 | 1 (Yes) |
#0055 (Additional parameters) |
bit 0 | 1 (ASCII) |
bit 1 | 0 (CR) |
bit 2 | 0 (Protocol A) |
bit 3 | 0 (RS232) |
Set the following parameters on the PC
Serial port tab
Machine name | Fanuc O-TC |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A#0D#0D
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Fanuc MSC-516
Fanuc 6T
Futaba CMC 320
GE Mark Century 1050
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.