Set the following parameters on the machine
P123 (ASCII mode) | Bit 4 = 2 |
P124 (Data bits) | 7 |
P125 (Parity) | 2 (Even) |
P126 (Stop bits) | 1 (One) |
P127 (Baud rate) | 9600 |
Set the following parameters on the PC
Serial port tab
Machine name | Futaba CMC 320 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | True |
Set DTR | True |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: % Program end: % Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |