Set the following parameters on the machine
In the 'SET' mode select manual input mode and set following parameters | |
IO CHANNEL | 0 |
PUNCH CODE | 1 |
TV CHECK | 0 |
Please, select following mode Offset Setting | System | Parameter (setting) and set following parameters | |
#0000 | 0000 0010 |
#0020 (IO Channel) | 0 (RS232) |
#0100 | 0 |
#0101 (NFD) | 1000 0001 |
#0102 (Device number) | 0 |
#0103 | 9 |
If you want you can change baud rate in the parameter #0103 to: | |
Baud | Parameter value |
1200 | 8 |
2400 | 9 |
4800 | 10 |
9600 | 11 |
19200 | 12 |
Set the following parameters on the PC
Serial port tab
Machine name | Fanuc MSC-516 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: % Program end: % Line start: Line end: #0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |