bg

DNC and CNC setting for Yaskawa - Yasnac LX-1

These settings are for the DNC Precision software only. They may not work with other software.

Set the following parameters on the machine

6026 (baud rate)0001 1000 (2400)
6028 (baud rate)0001 1000 (2400)
Change following bits in the parameter #6000 only
bit 71 (ISO format)
Change following bits in the parameter #6003 only
bit 51
bit 11
Change following bits in the parameter #6021 only
bit 60
bit 50
bit 40
bit 10
Change following bits in the parameter #6022 only
bit 11
bit 01

Set the following parameters on the PC

Serial port tab

Machine nameYaskawa - Yasnac LX-1
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRTrue
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 