DNC and CNC setting for Yaskawa - Yasnac MX-2
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
6026 (baud rate) | 0001 1000 (2400) |
6028 (baud rate) | 0001 1000 (2400) |
Change following bits in the parameter #6000 only |
bit 7 | 1 (ISO format) |
Change following bits in the parameter #6003 only |
bit 5 | 1 |
bit 1 | 1 |
Change following bits in the parameter #6021 only |
bit 6 | 0 |
bit 5 | 0 |
bit 4 | 0 |
bit 1 | 0 |
Change following bits in the parameter #6022 only |
bit 1 | 1 |
bit 0 | 1 |
Set the following parameters on the PC
Serial port tab
Machine name | Yaskawa - Yasnac MX-2 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | True |
Set DTR | True |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Yaskawa - Yasnac LX-1
Yaskawa - Yasnac MX-1
You Ji CNC
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.