DNC and CNC setting for Yaskawa - Yasnac 2000G
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Parameter 59 | X set at 3 |
Parameter 59 | Z defines a baud rate |
Select the Z values from the list |
110 baud rate | 37327 |
300 baud rate | 54734 |
600 baud rate | 27598 |
1200 baud rate (recommended) | 13774 |
2400 baud rate (recommended) | 7118 |
4800 baud rate (recommended) | 54733 |
9600 baud rate (recommended) | 54733 |
Set the following parameters on the PC
Serial port tab
Machine name | Yaskawa - Yasnac 2000G |
Serial port | COM2 (or any free COM port) |
Baud | 1200 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | True |
Set DTR | True |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Wenzler MTA-6
Wenzler MTA-8
Yaskawa - Yasnac LX-1
Yaskawa - Yasnac MX-1
Yaskawa - Yasnac MX-2
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.