DNC and CNC setting for Siemens - Sinumerik 3M
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
411 | 1110 1111 |
412 | 1110 1111 |
To change parameter type: | N411S11101111 |
Change only following bits in the parameter #416 |
bit 7 | 1 |
bit 0 | 1 |
If you want you can change baud rate |
Baud | Parameter value |
600 | 1110 1011 |
1200 | 1110 1100 |
2400 | 1110 1101 |
4800 | 1110 1110 |
9600 | 1110 1111 |
Set the following parameters on the PC
Serial port tab
Machine name | Siemens - Sinumerik 3M |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | True |
Set DTR | True |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: MPF
Program starting characters in the file: No
Program ending characters in the file: Yes |
Straight cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Straight cable, with full handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Straight cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Straight cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Phillips - Maho 432
Pro Elesta
Siemens - Sinumerik 3T
Siemens - Sinumerik 802D
Siemens - Sinumerik 810M
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.