DNC and CNC setting for Fanuc 0I-M
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Set to MDI mode or emergency stop state |
Press function key several times or press soft key [SETTING] to display SETTING (HANDY) screen. |
Set the cursor to PARAMETER WRITE and, press and keys in this order. Here alarm 100 will be displayed. |
Press function key several times to display parameters screen. |
. Set the following parameters: |
IO CHANNEL | 0 |
TAPE FORMAT | 0 |
PUNCH CODE | 1 |
TV CHECK | 0 |
Please, select following mode 'Offset Setting -> System -> Parameter (setting) and set following parameters |
#0000 (ISO mode) | 0000 0010 (TVC=0, TV check off; ISO=1, ISO mode enabled) |
#0020 (IO Channel) | 0 (Channel 1, RS232, JD56A of mother board) |
#0100 (Program format) | NCR=1, CRF=0, Line end format: LF, ND3=1 - drip feed mode |
#0101 (Stop bit and other data) | 1000 0001 (NFD=1, Feed is not output; ASI=0, ISO mode; SB2=1, two stop bits) |
#0102 (Device number) | 0 (RS-232) |
#0103 (Baud rate) | 9 (2400) |
#0134 (Parity) | PRY=1 (Use parity checking, power off/on machine after changing) |
If you want you can change baud rate in the parameter #0103 to: |
Baud | Parameter value |
1200 | 8 |
2400 | 9 |
4800 | 10 |
9600 | 11 |
19200 | 12 |
Set the following parameters on the PC
Serial port tab
Machine name | Fanuc 0I-M |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Fagor 8040/8050
Fanuc 0-P
Fanuc 0I-T
Fanuc 0M-C
Fanuc 0M-D
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.