Set the following parameters on the machine

P0 (baud rate)7 (9600)
P1 (data bits)1 (8 data bits)
P2 (parity)0 (no parity)
P3 (stop bits)0 (one stop bit)
P4 (protocol type)0 (general device)
P5 (Fagor DNC is active)No
P6 (Debug)No
P7 (Abort characters)0
P8 (EOL characters)0 (LF)
P9 (EOT characters)0
P10 (Xon and Xoff)Yes
If you want you can change baud rate in the parameter P0 to:
BaudParameter value
12004
24005
48006
96007
192008
384009
5760010

Set the following parameters on the PC

Serial port tab

Machine nameFagor 8040/8050
Serial portCOM2 (or any free COM port)
Baud9600
Data bits8
ParityNone
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSFalse
Set RTSFalse
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Fagor 8025
Fagor 8030
Fanuc 0-P
Fanuc 0I-M
Fanuc 0I-T