DNC and CNC setting for Fagor 8030
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8030 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Fagor 8020
Fagor 8025
Fagor 8040/8050
Fanuc 0-P
Fanuc 0I-M
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.