DNC and CNC setting for Fagor
These settings are for the DNC Precision software only. They may not work with other software.
Fagor 800 - DNC settings
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 800 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Fagor 8010 - Machine parameters
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8010 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Fagor 8020 - DNC settings
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8020 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Fagor 8025 - Machine parameters
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8025 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Fagor 8030 - NC settings
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8030 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Fagor 8040/8050 - Machine parameters
Set the following parameters on the machine
P0 (baud rate) | 7 (9600) |
P1 (data bits) | 1 (8 data bits) |
P2 (parity) | 0 (no parity) |
P3 (stop bits) | 0 (one stop bit) |
P4 (protocol type) | 0 (general device) |
P5 (Fagor DNC is active) | No |
P6 (Debug) | No |
P7 (Abort characters) | 0 |
P8 (EOL characters) | 0 (LF) |
P9 (EOT characters) | 0 |
P10 (Xon and Xoff) | Yes |
If you want you can change baud rate in the parameter P0 to: |
Baud | Parameter value |
1200 | 4 |
2400 | 5 |
4800 | 6 |
9600 | 7 |
19200 | 8 |
38400 | 9 |
57600 | 10 |
Set the following parameters on the PC
Serial port tab
Machine name | Fagor 8040/8050 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Fadal VMC
Ellison Technologies - Puma VT900
Fanuc 0-P
Fanuc MSC-516
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.