Schneider Electric PowerLogic ION7300 data logging - MODBUS registers map
The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These tools provide continuous and reliable Schneider Electric PowerLogic ION7300 data logging and read.
MODBUS offset Description Units Data type
10 Vln a, Modbus Slave 1 word
11 Vln b, Modbus Slave 1 word
12 Vln c, Modbus Slave 1 word
13 Vln avg, Modbus Slave 1 word
14 Vll ab, Modbus Slave 1 word
15 Vll bc, Modbus Slave 1 word
16 Vll ca, Modbus Slave 1 word
17 Vll avg, Modbus Slave 1 word
18 I a, Modbus Slave 1 word
19 I b, Modbus Slave 1 word
20 I c, Modbus Slave 1 word
21 I avg, Modbus Slave 1 word
22 V unbal, Modbus Slave 1 V word
23 I unbal, Modbus Slave 1 word
24 Freq, Modbus Slave 1 word
25 Phase Rev, Modbus Slave 1 word
26 kW a, Modbus Slave 2 kW integer
28 kW b, Modbus Slave 2 kW integer
30 kW c, Modbus Slave 2 kW integer
32 kW tot, Modbus Slave 2 kW integer
34 kVAR a, Modbus Slave 2 kVAR integer
36 kVAR b, Modbus Slave 2 kVAR integer
38 kVAR c, Modbus Slave 2 kVAR integer
40 kVAR tot, Modbus Slave 2 kVAR integer
42 kVA a, Modbus Slave 2 kVA integer
44 kVA b, Modbus Slave 2 kVA integer
46 kVA c, Modbus Slave 2 kVA integer
48 kVA tot, Modbus Slave 2 kVA integer
50 PF sign a, Modbus Slave 2 integer
52 PF sign b, Modbus Slave 2 integer
54 PF sign c, Modbus Slave 2 integer
56 PF sign tot, Modbus Slave 2 integer
58 kW td, Modbus Slave 3 kW integer
60 kVAR td, Modbus Slave 3 kVAR integer
62 kVA td, Modbus Slave 3 kVA integer
64 kW td mx, Modbus Slave 3 kW integer
66 kVAR td mx, Modbus Slave 3 kVAR integer
68 kVA td mx, Modbus Slave 3 kVA integer
70 Vln avg mx, Modbus Slave 3 integer
72 I avg mx, Modbus Slave 3 integer
74 kW tot mx, Modbus Slave 3 kW integer
76 kVAR tot mx, Modbus Slave 3 kVAR integer
78 kVA tot mx, Modbus Slave 3 kVA integer
80 Freq mx, Modbus Slave 3 integer
82 Vln avg mn, Modbus Slave 3 integer
84 I avg mn, Modbus Slave 3 integer
86 Freq mn, Modbus Slave 3 integer
88 kWh imp (kWh del) 1, Modbus Slave 4 kWh integer
90 kWh exp (kWh rec) 1, Modbus Slave 4 kWh integer
92 kWh tot (kWh del+rec) 1, Modbus Slave 4 kWh integer
There are more MODBUS items for this device. Please download the program to discover all registers.
Related MODBUS registers maps
Schneider Electric PowerLogic EM4800
Schneider Electric PowerLogic ION6200
Schneider Electric PowerLogic ION7400
Schneider Electric PowerLogic ION7500-ION7600
Schneider Electric PowerLogic ION7550-ION7650