bg

« This program is just what I was looking for - something which is adaptable by "non-programmers" such as myself to our many and rapidly changing applications and equipment configurations. »

Advanced TCP/IP Data Logger: Capture & Log Network Traffic Data

For Windows 2000 - Windows 11 (2022) (incl. Server, x86 and x64). Latest version: 5.0.4 build 1211. December 11, 2024.

TCP/IP or UDP data logger - allows capturing network traffic and send data to any database or other applications    

Brief description:

Advanced TCP/IP Data Logger inputs TCP/IP, UDP, or HTTP data directly into a file, Excel, MS Access, or any Windows application. Advanced TCP/IP Data Logger provides real-time data collection from any device or instrument and sends and receives IP data across the Internet or local network connection.

Our software captures IP data, parses it into data packets and data items, and sends parsed data to other targets like an ODBC- or OLE-compatible database, file, or another application. The logger can bypass the data to other systems through OPC or DDE interfaces. Additionally, you may integrate the logger to your online application by calling your HTTP API or send data to the Internet through email, FTP, or SFTP. It allows you to implement simple and complex automatization tasks shortly without special programming.

What problems can be solved with Advanced TCP/IP Data Logger?

A typical application for Advanced TCP/IP Data Logger is to log data from one or more Terminal Servers to disk. A Terminal Server is a device that allows RS232 or RS485 serial devices to be connected directly to an Ethernet network. Terminal Servers typically have an Ethernet connector and one or more RS232 or RS485 ports, and they use the TCP/IP network protocol by sending the data that is transmitted through the RS232 or RS485 serial port to a TCP/IP port. Each Terminal Server would have its own IP address, and all serial data would be sent through a specific TCP/IP port number.

Another typical application is remote access to an RS232 or RS485 controlled technology. I/O controller is an ideal device if you need remote digital I/O signalizations (Ethernet input, Ethernet output), remote relay control, server accessible remote inputs together with an RS-232 or RS-485 bus for a bar code reader, display, etc.

Getting started is easy. Advanced TCP/IP Data Logger is ready!

After installation, start Advanced TCP/IP Data Logger from the Start Menu. Choose the communication parameters for your network device. Then define how you want the data to be parsed and translated.

Screenshot:

TCP/IP data logger Overview More screenshots

Features:

Capability to log multiple TCP/IP or UDP ports at the same time Our data logger can log multiple ports simultaneously so that multiple external serial devices can be logged.

Universal. Can work as a server or a client.

Variable data receive. Supports text, raw, binary data, and many popular communication protocols.

Powerful data logging features. The program can log sent and received data without any changes to a file. Variable format file forming setting (on time, data, size, etc.).

Advanced data parsers. Allow you to parse, filter, and format your data. You may define simple rules or use powerful regular expressions.

Databases support. Data export to any ODBC- or SQL-compatible database (MS SQL, Oracle, MS Access, MySQL, and others).

Cloud databases. Data export to the most popular cloud databases (Microsoft Azure, MySQL, PostgreSQL, MariaDB, MongoDB, Amazon Aurora, Amazon Redshift).

Industrial real-time export capabilities. Advanced TCP/IP Data Logger can run as DDE or OPC server and can public all received data.

Office product integrations. The logger can send data to Microsoft Excel, OpenOffice, Google Sheets, to rows or columns.

The auto program restart. The program can restart daily at the specified time. It allows you to change the program configuration remotely.

Program message logging. The logger can record all program messages to a file so that you may diagnose errors and warnings and control the program when it works in the service mode.

Plugins. Many plugin modules extend program features.

Simple, menu-driven step-by-step setup Programming is not required to configure the software to collect data.

Various OS. Works on all Windows since Windows 2000.

Windows service mode. Advanced TCP/IP Data Logger also is a Windows service that records all data received on a serial port to a file on a disk or to other targets so that it starts as soon as the operating system starts and doesn't require a user to log in and run it. It will continue to run even as users log on and log off the workstation. However, Advanced TCP/IP Data Logger is generic enough to be useful whenever one-way serial traffic needs to be recorded.

It is straightforward to use! The configuration process is fully menu-driven and has complete, context-sensitive, online help. Once you see how easy it is to use Advanced TCP/IP Data Logger, you will never again take data readings by hand!