bg

DNC and CNC setting for Yaskawa

These settings are for the DNC Precision software only. They may not work with other software.

Yaskawa - Yasnac 2000G - DNC settings

Set the following parameters on the machine

Parameter 59X set at 3
Parameter 59Z defines a baud rate
Select the Z values from the list
110 baud rate37327
300 baud rate54734
600 baud rate27598
1200 baud rate (recommended)13774
2400 baud rate (recommended)7118
4800 baud rate (recommended)54733
9600 baud rate (recommended)54733

Set the following parameters on the PC

Serial port tab

Machine nameYaskawa - Yasnac 2000G
Serial portCOM2 (or any free COM port)
Baud1200
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSFalse
Set RTSTrue
Set DTRTrue
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No

Yaskawa - Yasnac LX-1 - Machine parameters

Set the following parameters on the machine

6026 (baud rate)0001 1000 (2400)
6028 (baud rate)0001 1000 (2400)
Change following bits in the parameter #6000 only
bit 71 (ISO format)
Change following bits in the parameter #6003 only
bit 51
bit 11
Change following bits in the parameter #6021 only
bit 60
bit 50
bit 40
bit 10
Change following bits in the parameter #6022 only
bit 11
bit 01

Set the following parameters on the PC

Serial port tab

Machine nameYaskawa - Yasnac LX-1
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRTrue
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Yaskawa - Yasnac MX-1 - DNC settings

Set the following parameters on the machine

6026 (baud rate)0001 1000 (2400)
6028 (baud rate)0001 1000 (2400)
Change following bits in the parameter #6000 only
bit 71 (ISO format)
Change following bits in the parameter #6003 only
bit 51
bit 11
Change following bits in the parameter #6021 only
bit 60
bit 50
bit 40
bit 10
Change following bits in the parameter #6022 only
bit 11
bit 01

Set the following parameters on the PC

Serial port tab

Machine nameYaskawa - Yasnac MX-1
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRTrue
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Yaskawa - Yasnac MX-2 - NC settings

Set the following parameters on the machine

6026 (baud rate)0001 1000 (2400)
6028 (baud rate)0001 1000 (2400)
Change following bits in the parameter #6000 only
bit 71 (ISO format)
Change following bits in the parameter #6003 only
bit 51
bit 11
Change following bits in the parameter #6021 only
bit 60
bit 50
bit 40
bit 10
Change following bits in the parameter #6022 only
bit 11
bit 01

Set the following parameters on the PC

Serial port tab

Machine nameYaskawa - Yasnac MX-2
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRTrue
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Wenzler MTA-8
Viking 150T
You Ji CNC

If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.