Set the following parameters on the machine
PARA1 | 0000 0000 |
PARA2 | 0000 0010 |
PARA3 | 0000 0100 |
PARA4 | 0000 0000 |
PARA5 | 0000 0000 |
PARA6 | 0000 0000 |
PARA7 | 0000 0000 |
PARA8 | 0000 0000 |
PARA9 | 0000 0000 |
Set the following parameters on the PC
Serial port tab
Machine name | Tanaka |
Serial port | COM2 (or any free COM port) |
Baud | 1200 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: Program end: Line start: Line end: #0D#0A Skip lines: Ignore characters: No characters for remove Remove blank lines: No Program name prefix: O Program starting characters in the file: No Program ending characters in the file: No |