DNC and CNC setting for Siemens - Sinumerik 840D
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Serial | 1 |
Device | Standard |
Device type | Universal |
Protocol | RTS/CTS (Hardware) |
Baud rate | 9600 |
Stop bits | 2 |
Parity | Even |
Bits per character | 7 |
Xon character | 11 |
Xoff character | 13 |
EOT | 03 |
Leader/trailer | N |
EOB | CRLF |
Timeout | 60 |
Format | Punch tape format |
Set the following parameters on the PC
Serial port tab
Machine name | Siemens - Sinumerik 840D |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: MPF
Program starting characters in the file: No
Program ending characters in the file: Yes |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Siemens - Sinumerik 810T
Siemens - Sinumerik 840C
Siemens - Sinumerik 850M
Siemens - Sinumerik 850T
Siemens - Sinumerik 8M
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.