Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC
Serial port tab
Machine name
Okuma - Okuma OSP 5000
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC
Serial port tab
Machine name
Okuma - Okuma OSP 5000M
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC
Serial port tab
Machine name
Okuma - Okuma OSP 5020L
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write]
Reading from the PC
Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write]
Set the following parameters on the PC
Serial port tab
Machine name
Okuma - Okuma OSP 7000
Serial port
COM2 (or any free COM port)
Baud
4800
Data bits
7
Parity
Even
Stop bits
1
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
Both
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
With help of the [PAGE DOWN] button go to tape interface (RS232 - CN0) parameters
Parameter
Value
1 (stop bits)
1
2 (parity check)
0
3 (parity)
1 (Even)
4 (8 bit JIS)
1 (Yes)
5 (DC2/DC4)
0 (No)
6 (file name read)
1 (Execute)
7 (CNC slave)
0 (No, master)
8 (baud rate)
9600
9 (busy timeout)
15
Set the following parameters on the PC
Serial port tab
Machine name
Okuma - Okuma OSP-U100
Serial port
COM2 (or any free COM port)
Baud
9600
Data bits
7
Parity
Even
Stop bits
2
Data flow control tab
Use DTR
False
Use RTS
True
Require DSR
False
Require CTS
True
Set RTS
False
Set DTR
False
Software flowcontrol
None
Xon char
#11
Xoff char
#13
Data exchange format tab
Format mode
Uniform
Format parameters
Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No
Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No