DNC and CNC setting for Mitsubishi
These settings are for the DNC Precision software only. They may not work with other software.
Mitsubishi - 300 - 500 - Machine parameters
Set the following parameters on the machine
Use different devices for input and output, but with same port number |
IO device parameters #1 |
Parameter | Value |
2 (baud rate) | 2 (4800) |
3 (stop bits) | 3 (two stop bits) |
4 (parity enabled) | 0 (No) |
5 (parity) | 1 (Even) |
6 (data bits) | 3 (8 dat bits) |
7 (termintator type) | 3 (EOR) |
11 (handshake) | 3 (DC codes) |
12 (parity on DC) | 1 (Yes) |
IO parameters screen #2 |
Parameter | Value |
1 (DC2 and DC4) | 1 (DC2 only) |
2 (CR) | 1 (Yes) |
3 (EIA output) | 0 (No, ISO) |
6 (Parity V) | 0 (No) |
7 (Timeout) | 200 (200 sec) |
Set the following parameters on the PC
Serial port tab
Machine name | Mitsubishi - 300 - 500 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 8 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mitsubishi - M50 - NC settings
Set the following parameters on the machine
Use different devices for input and output, but with same port number |
IO parameters screen 1/6 |
9001 (In port #) | 2 |
9002 (In device #) | 1 |
9003 (Out port #) | 2 |
9004 (Out device #) | 0 |
9005 (Tape mode) | 2 |
IO parameters screen 2/6 |
9101 | OUT/IN |
9102 (baud rate) | 2 (4800) |
9103 (stop bits) | 1 (one stop bit) |
9104 (add parity) | 1 (Yes) |
9105 (parity) | 1 (Even) |
9106 (data bits) | 2 (7 data bits) |
9108 (use DC codes) | 3 (yes, DC1 and DC3) |
9109 (no parity for DC codes) | 1 (Yes) |
9112 (CR output) | 1 (Yes) |
9113 (EIA output) | 0 (No) |
9114 (Feed chr.) | 0 (No) |
IO parameters screen 3/6 |
9201 | OUT/IN |
9202 (baud rate) | 2 (4800) |
9203 (stop bits) | 1 (one stop bit) |
9204 (add parity) | 1 (Yes) |
9205 (parity) | 1 (Even) |
9206 (data bits) | 2 (7 data bits) |
9208 (use DC codes) | 3 (yes, DC1 and DC3) |
9209 (no parity for DC codes) | 1 (Yes) |
9212 (CR output) | 1 (Yes) |
9213 (EIA output) | 0 (No) |
9214 (Feed chr.) | 0 (No) |
Set the following parameters on the PC
Serial port tab
Machine name | Mitsubishi - M50 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: #00#00%%#00#00
Program end: #00#00%%#00#00
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mitsubishi - DWC110 W6 - DNC settings
Set the following parameters on the machine
Baud rate | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Drip-feed mode | Not available |
Set the following parameters on the PC
Serial port tab
Machine name | Mitsubishi - DWC110 W6 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mitsubishi - Meldas 60 Series - Machine parameters
Set the following parameters on the machine
Use different devices for input and output, but with same port number |
IO parameters screen 1/6 |
9001 (In port #) | 2 |
9002 (In device #) | 1 |
9003 (Out port #) | 2 |
9004 (Out device #) | 0 |
9005 (Tape mode) | 2 |
IO parameters |
9101,9201 | IN,OUT |
9102,9202 (baud rate) | 2 (4800) |
9103,9203 (stop bits) | 1 (one stop bit) |
9104,9204 (add parity) | 1 (Yes) |
9105,9205 (parity) | 1 (Even) |
9106,9206 (data bits) | 2 (7 data bits) |
9108,9208 (use DC codes) | 3 (yes, DC1 and DC3) |
9109,9209 (no parity for DC codes) | 1 (Yes) |
9112,9212 (CR output) | 1 (Yes) |
9113,9213 (EIA output) | 0 (No) |
9114,9214 (Feed chr.) | 0 (No) |
Set the following parameters on the PC
Serial port tab
Machine name | Mitsubishi - Meldas 60 Series |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page