DNC and CNC setting for Okuma - Okuma OSP 5000
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Optional Parameter Word |
1 (no tape leader/trailer) | 0 |
34 (time before alarm) | 30 |
39 (baud rate) | 4800 |
44 (punch device) | 0 |
45 (input device) | 0 |
46 (output device) | 0 |
54 (read device) | 1 |
57 (time before alarm) | 90 |
Optional Parameter Bit #1 - 0000 1011 |
1.0 (Auto parity check: yes) | 1 |
1.1 (ISO code: yes) | 1 |
1.2 (Tape vertical check: no) | 0 |
1.3 (Delimiter %) | 1 |
1.4 (Verify at read: no) | 0 |
1.5 (Special code read: no) | 0 |
1.6 (Special code alarm: no) | 0 |
1.7 (Special code ignored: no) | 0 |
Optional Parameter Bit #12 - 1010 1010 |
12.0 (1 stop bit: yes) | 0 |
12.1 (No ready sig.: none) | 1 |
12.2 (Parity check: no) | 0 |
12.3 (Even parity: 1 - even, 0 - odd) | 1 |
12.4 (8 data bits: no) | 0 |
12.5 (DC code: yes) | 1 |
12.6 (DC code type 2: no) | 0 |
12.7 (File name read: yes) | 1 |
Input/output operations |
Sending to the PC | Go to the 'Edit/AUX mode', [F3] (PIP), [F2] (Punch), type file name, then [Return] or [Write] |
Reading from the PC | Go to the 'Edit/AUX mode', [F3] (PIP), [F1] (Read), [Return] or [Write] |
Set the following parameters on the PC
Serial port tab
Machine name | Okuma - Okuma OSP 5000 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Okuma - Okuma 100-EL
Okuma - Okuma OSP 5000M
Okuma - Okuma OSP 5020L
Okuma - Okuma OSP 7000
Okuma - Okuma OSP-U100
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.