DNC and CNC setting for Mazak
These settings are for the DNC Precision software only. They may not work with other software.
Mazak - Fusion 640M - Machine parameters
Set the following parameters on the machine
Baud rate | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Handshake | DC control |
Wait time | 45 sec |
Format | 7 |
Same Wno. | ALARM |
Port | COM1 |
TAP1 | 1 |
TAP2 | 0 |
TAP3 | 0 |
TAP4 | 0 |
TAP5 | 1 |
TAP6 | 0 |
TAP7 | 0 |
TAP8 | 8 |
TAP9 | 76 |
TAP10 | 13 |
TAP11 | 109 |
TAP12 | 122 |
TAP13 | 91 |
TAP14 | 70 |
TAP15 | 0 |
TAP16 | 0 |
TAP17 | 0 |
TAP18 | 0 |
TAP19 | 0 |
TAP20 | 0 |
TAP21 | 0 |
TAP22 | 0 |
TAP23 | 0 |
TAP24 | 0 |
TAP25 | 00000000 |
TAP26 | 00000001 |
TAP27 | 00000000 |
TAP28 | 00111010 |
TAP29 | 10 |
TAP30 | 30 |
TAP31 | 0 |
TAP32 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - Fusion 640M |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - Fusion 640T - DNC settings
Set the following parameters on the machine
Baud rate | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Handshake | DC control |
Wait time | 45 sec |
Format | 7 |
Same Wno. | ALARM |
Port | COM1 |
TAP1 | 1 |
TAP2 | 0 |
TAP3 | 0 |
TAP4 | 0 |
TAP5 | 1 |
TAP6 | 0 |
TAP7 | 0 |
TAP8 | 8 |
TAP9 | 76 |
TAP10 | 13 |
TAP11 | 109 |
TAP12 | 122 |
TAP13 | 91 |
TAP14 | 70 |
TAP15 | 0 |
TAP16 | 0 |
TAP17 | 0 |
TAP18 | 0 |
TAP19 | 0 |
TAP20 | 0 |
TAP21 | 0 |
TAP22 | 0 |
TAP23 | 0 |
TAP24 | 0 |
TAP25 | 00000000 |
TAP26 | 00000001 |
TAP27 | 00000000 |
TAP28 | 00111010 |
TAP29 | 10 |
TAP30 | 30 |
TAP31 | 0 |
TAP32 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - Fusion 640T |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - L32 - DNC settings
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
Change CNC parameters |
FD I/O Mode | 1 (ISO) |
FD I/O STOP BIT | 2 (2 bits) |
FD I/O PARITY | 0 (No Parity, but in DNCP you should use the Even parity) |
FD I/O BAUD RATE | 9600 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - L32 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: Yes
Program ending characters in the file: Yes |
Mazak - M plus - NC settings
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
Change user parameter #5 |
G1 (baud rate) | 1 (9600) |
G2 (stop bits) | 3 (2 stop bits) |
G3 (parity) | 0 (Even) |
G5 (data bits) | 3 (8 data bits, but in the program you should specify 7 ) |
G6 (Terminattors) | 1 (EOB or EOR) |
G10 | 3 (Use DC handshaking) |
G11 | 1 (Parity on DC output) |
G12 | 0 (Don't output DC2 and DC4) |
G13 (wait time) | 50 |
G17 | 00000000 |
G31 | 00000000 |
G33 (feed section size) | 50 |
G34 (number of spaces) | 10 |
G39 | 00000100 |
G40 | 00000000 |
G48 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - M plus |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - M32 plus - Machine parameters
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
Change user parameter #5 |
G1 (baud rate) | 2 (4800) |
G2 (stop bits) | 3 (2 stop bits) |
G3 (parity) | 0 (Even) |
G5 (data bits) | 3 (8 data bits, but in the program you should specify 7 ) |
G6 (Terminattors) | 1 (EOB or EOR) |
G7 | 0 |
G8 | 0 |
G9 | 0 |
G10 | 1 |
G11 | 1 |
G12 | 0 |
G13 (wait time) | 50 |
G14 | 0 |
G15 | 0 |
G16 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - M32 plus |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - M32 - DNC settings
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
Change user parameter #5 |
G19 (baud rate) | 2 (4800) |
G20 (stop bits) | 3 (2 stop bits) |
G22 (parity) | 0 (Even) |
G23 (data bits) | 3 (8 data bits, but in the program you should specify 7 ) |
G24 | 1 |
G25 | 0 |
G26 | 0 |
G27 (ISO CR output) | 0 |
G28 | 0 |
G29 (handshake type) | 3 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - M32 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - T plus - NC settings
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
I1 | 2 |
I2 | 3 |
I3 | 0 |
I4 | 0 |
I5 | 3 |
I6 | 3 |
I7 | 1 |
I8 | 5 |
I9 | 0 |
I10 | 1 |
I11 | 1 |
I12 | 0 |
I13 | 0 |
I14 | 0 |
I15 | 30 |
I16 | 0 |
I24 | 0 |
I58 | 0000 0000 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - T plus |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 8 |
Parity | None |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - T2 - Machine parameters
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
A15 (RS-232) | 206 |
A16 (parity) | 1 (None, but in a program configuration you should specify 7 data bits and Even parity) |
A17 (baud rate) | 6 (4800) |
A18 (mode) | 6 (read and punch) |
A19 | 0 |
A20 (punch code) | 1 (ISO) |
A21 | 1 |
A22 | 10 |
A23 | 10 |
A24 (TV check) | 0 |
A30 | 3 |
A31 | 109 |
A31 | 70 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - T2 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Mazak - T32 M2 - NC settings
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
I1 | 2 |
I2 | 3 |
I3 | 0 |
I4 | 0 |
I5 | 3 |
I6 | 3 |
I7 | 1 |
I8 | 5 |
I9 | 0 |
I10 | 1 |
I11 | 1 |
I12 | 0 |
I13 | 0 |
I14 | 0 |
I15 | 30 |
I16 | 0 |
I24 | 0 |
I58 | 0000 0000 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - T32 M2 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page