DNC and CNC setting for Mazak - M32
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Note: | The program does not support the Mazatrol protocol |
Change user parameter #5 |
G19 (baud rate) | 2 (4800) |
G20 (stop bits) | 3 (2 stop bits) |
G22 (parity) | 0 (Even) |
G23 (data bits) | 3 (8 data bits, but in the program you should specify 7 ) |
G24 | 1 |
G25 | 0 |
G26 | 0 |
G27 (ISO CR output) | 0 |
G28 | 0 |
G29 (handshake type) | 3 |
Set the following parameters on the PC
Serial port tab
Machine name | Mazak - M32 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: :
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Mazak - M plus
Mazak - M32 plus
Mazak - T plus
Mazak - T2
Mazak - T32 M2
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.