DNC and CNC setting for Leadwell - V80i
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the PC
Serial port tab
Machine name | Leadwell - V80i |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0A
Skip lines:
Ignore characters: #0D
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: Yes
Program ending characters in the file: Yes |
Go to Index page
Leadwell - V20i
Leadwell - V50i
Maho - CNC 432 - 1000
Maho - CNC 432 - 2000
Mazak - Fusion 640M
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.