DNC and CNC setting for Huller - Hille
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the PC
Serial port tab
Machine name | Huller - Hille |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Data reception |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: ;_N_CZR
Program starting characters in the file: No
Program ending characters in the file: No |
Go to Index page
Hinumerik 3000T
Hitachi Seikos
Hurco - Ultimax
Indramat system 200
Kitamura - HX300
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.