Set the following parameters on the machine

50100
501111000101
50120
501311000101
RTS line1
Change following bits in the parameter #5016 only
bit 51
bit 40
If you want, you can change baud rate (#5011,#5013)
BaudParameter value
120011000100
240011000101
480011000110
960011000111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 2100T
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 