DNC and CNC setting for Heidenhain
These settings are for the DNC Precision software only. They may not work with other software.
Heidenhain-CNC Pilot - Machine parameters
Set the following parameters on the machine
Press the [Parameter] button, then select Configure, then Control direct, then Enter parameter #42 and change |
Baud rate | 15 (19200) |
Word length | 1 (7 bits) |
Parity | 1 (Even) |
Stop bits | 0 (One) |
Protocol | 0 (Hardware) |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-CNC Pilot |
Serial port | COM2 (or any free COM port) |
Baud | 19200 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 145 - NC settings
Set the following parameters on the machine
Enter to editing parameters mode by 95148 code. Press [DEL] twice for exit. |
Interface type | EXT |
Baud rate | 9600 |
MP222 (data format) | 104 |
MP92 (multi function) | 1 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 145 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: PGM
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 150 - Machine parameters
Set the following parameters on the machine
Enter to editing parameters mode by 95148 code. Press [DEL] twice for exit. |
Interface type | EXT |
Baud rate | 9600 |
MP222 (data format) | 104 |
MP92 (multi function) | 1 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 150 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: PGM
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 155 - NC settings
Set the following parameters on the machine
Enter to editing parameters mode by 95148 code. Press [DEL] twice for exit. |
Interface type | EXT |
Baud rate | 9600 |
MP222 (data format) | 104 |
MP92 (multi function) | 1 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 155 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: PGM
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 2500 - Machine parameters
Set the following parameters on the machine
MP5200 (data format) | 100 |
MP5030 (interface type) | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 2500 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 407 - Machine parameters
Set the following parameters on the machine
Interface type | EXT2 |
Baud rate | 9600 |
MP5200.1 (external device) | 2 |
MP5201.1 (external device) | 3 |
MP5020.1 | 104 |
MP5030.1 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 407 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 415B - Machine parameters
Set the following parameters on the machine
Interface type | EXT2 |
Baud rate | 9600 |
MP5200.1 (external device) | 2 |
MP5201.1 (external device) | 3 |
MP5020.1 | 104 |
MP5030.1 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 415B |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Heidenhain-TNC 425 - DNC settings
Set the following parameters on the machine
Interface type | EXT2 |
Baud rate | 9600 |
MP5200.1 (external device) | 2 |
MP5201.1 (external device) | 3 |
MP5020.1 | 104 |
MP5030.1 | 0 |
Set the following parameters on the PC
Serial port tab
Machine name | Heidenhain-TNC 425 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Haas Mill
Haas Lathe
Hinumerik 2000M
Hitachi Seikos
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.