DNC and CNC setting for Hinumerik
These settings are for the DNC Precision software only. They may not work with other software.
Hinumerik 2000M - NC settings
Set the following parameters on the machine
5010 | 0 |
5011 | 11000101 |
5012 | 0 |
5013 | 11000101 |
RTS line | 1 |
Change following bits in the parameter #5016 only |
bit 5 | 1 |
bit 4 | 0 |
If you want, you can change baud rate (#5011,#5013) |
Baud | Parameter value |
1200 | 11000100 |
2400 | 11000101 |
4800 | 11000110 |
9600 | 11000111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 2000M |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Hinumerik 2000T - DNC settings
Set the following parameters on the machine
5010 | 0 |
5011 | 11000101 |
5012 | 0 |
5013 | 11000101 |
RTS line | 1 |
Change following bits in the parameter #5016 only |
bit 5 | 1 |
bit 4 | 0 |
If you want, you can change baud rate (#5011,#5013) |
Baud | Parameter value |
1200 | 11000100 |
2400 | 11000101 |
4800 | 11000110 |
9600 | 11000111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 2000T |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Hinumerik 2100M - DNC settings
Set the following parameters on the machine
5010 | 0 |
5011 | 11000101 |
5012 | 0 |
5013 | 11000101 |
RTS line | 1 |
Change following bits in the parameter #5016 only |
bit 5 | 1 |
bit 4 | 0 |
If you want, you can change baud rate (#5011,#5013) |
Baud | Parameter value |
1200 | 11000100 |
2400 | 11000101 |
4800 | 11000110 |
9600 | 11000111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 2100M |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Hinumerik 2100T - Machine parameters
Set the following parameters on the machine
5010 | 0 |
5011 | 11000101 |
5012 | 0 |
5013 | 11000101 |
RTS line | 1 |
Change following bits in the parameter #5016 only |
bit 5 | 1 |
bit 4 | 0 |
If you want, you can change baud rate (#5011,#5013) |
Baud | Parameter value |
1200 | 11000100 |
2400 | 11000101 |
4800 | 11000110 |
9600 | 11000111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 2100T |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Hinumerik 3000M - DNC settings
Set the following parameters on the machine
Change following bits in the parameter #416 only |
bit 7 | 1 |
bit 0 | 0 |
If you want, you can change baud rate (#411,#412) |
Baud | Parameter value |
1200 | 11101100 |
2400 | 11101101 |
4800 | 11101110 |
9600 | 11101111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 3000M |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Hinumerik 3000T - DNC settings
Set the following parameters on the machine
Change following bits in the parameter #416 only |
bit 7 | 1 |
bit 0 | 0 |
If you want, you can change baud rate (#411,#412) |
Baud | Parameter value |
1200 | 11101100 |
2400 | 11101101 |
4800 | 11101110 |
9600 | 11101111 |
Set the following parameters on the PC
Serial port tab
Machine name | Hinumerik 3000T |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page