DNC and CNC setting for Hinumerik

These settings are for the DNC Precision software only. They may not work with other software.

Hinumerik 2000M - NC settings

Set the following parameters on the machine

50100
501111000101
50120
501311000101
RTS line1
Change following bits in the parameter #5016 only
bit 51
bit 40
If you want, you can change baud rate (#5011,#5013)
BaudParameter value
120011000100
240011000101
480011000110
960011000111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 2000M
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Hinumerik 2000T - DNC settings

Set the following parameters on the machine

50100
501111000101
50120
501311000101
RTS line1
Change following bits in the parameter #5016 only
bit 51
bit 40
If you want, you can change baud rate (#5011,#5013)
BaudParameter value
120011000100
240011000101
480011000110
960011000111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 2000T
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Hinumerik 2100M - DNC settings

Set the following parameters on the machine

50100
501111000101
50120
501311000101
RTS line1
Change following bits in the parameter #5016 only
bit 51
bit 40
If you want, you can change baud rate (#5011,#5013)
BaudParameter value
120011000100
240011000101
480011000110
960011000111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 2100M
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Hinumerik 2100T - Machine parameters

Set the following parameters on the machine

50100
501111000101
50120
501311000101
RTS line1
Change following bits in the parameter #5016 only
bit 51
bit 40
If you want, you can change baud rate (#5011,#5013)
BaudParameter value
120011000100
240011000101
480011000110
960011000111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 2100T
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Hinumerik 3000M - DNC settings

Set the following parameters on the machine

41111101101
41211101101
Change following bits in the parameter #416 only
bit 71
bit 00
If you want, you can change baud rate (#411,#412)
BaudParameter value
120011101100
240011101101
480011101110
960011101111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 3000M
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Hinumerik 3000T - DNC settings

Set the following parameters on the machine

41111101101
41211101101
Change following bits in the parameter #416 only
bit 71
bit 00
If you want, you can change baud rate (#411,#412)
BaudParameter value
120011101100
240011101101
480011101110
960011101111

Set the following parameters on the PC

Serial port tab

Machine nameHinumerik 3000T
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page