DNC and CNC setting for Dialog

These settings are for the DNC Precision software only. They may not work with other software.

Dialog-11 - DNC settings

Set the following parameters on the machine

DeviceChannel 1

Set the following parameters on the PC

Serial port tab

Machine nameDialog-11
Serial portCOM2 (or any free COM port)
Baud4800
Data bits7
ParityNone
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Dialog-2 - NC settings

Set the following parameters on the machine

The machine parameters can be set using the DIP switches available on the control panel.
This machine does not have an RS232C interface. K5 connector is available for audio interface must be connected to a DB-25 connector (which must be fixed to the panel)
DB25K5
111,12
217
313
420
516
618
711,12
6 connect with 20

Set the following parameters on the PC

Serial port tab

Machine nameDialog-2
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityNone
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Dialog-4 - NC settings

Set the following parameters on the PC

Serial port tab

Machine nameDialog-4
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityNone
Stop bits2

Data flow control tab

Use DTRFalse
Use RTSTrue
Require DSRFalse
Require CTSTrue
Set RTSFalse
Set DTRFalse
Software flowcontrolNone
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: &%
Program end: M30#0D#0A
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Delta Dynapath
DOOSAN HM630
Digma CNC
Eckelmann - Viewstar 750

If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.