Dialog-11 - DNC settings
Set the following parameters on the machine
Set the following parameters on the PC
Serial port tab
Machine name | Dialog-11 |
Serial port | COM2 (or any free COM port) |
Baud | 4800 |
Data bits | 7 |
Parity | None |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes |
Dialog-2 - NC settings
Set the following parameters on the machine
The machine parameters can be set using the DIP switches available on the control panel. |
This machine does not have an RS232C interface. K5 connector is available for audio interface must be connected to a DB-25 connector (which must be fixed to the panel) |
DB25 | K5 |
1 | 11,12 |
2 | 17 |
3 | 13 |
4 | 20 |
5 | 16 |
6 | 18 |
7 | 11,12 |
6 connect with 20 |
Set the following parameters on the PC
Serial port tab
Machine name | Dialog-2 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | None |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end: M30
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes |
Dialog-4 - NC settings
Set the following parameters on the PC
Serial port tab
Machine name | Dialog-4 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | None |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: &%
Program end: M30#0D#0A
Line start:
Line end: #0D#0A
Skip lines: ;
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix:
Program starting characters in the file: No
Program ending characters in the file: Yes |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Delta Dynapath
DOOSAN HM630
Digma CNC
Eckelmann - Viewstar 750
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.