DNC and CNC setting for Bosch alpha 3
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
You need to set the baud rate = 1200 |
Select edit parameters mode [MODE] [N+1] |
Output current the 'Baud' parameter value [A+1] [A+1] |
Clear current value |
Set parameter value = 7 |
Save changes |
The baud rate can be: |
50 bps | 0 |
75 bps | 1 |
110 bps | 2 |
134.5 bps | 3 |
150 bps | 4 |
200 bps | 5 |
600 bps | 6 |
1200 bps | 7 |
1800 bps | 8 |
2000 bps | 9 |
2400 bps | 10 |
3600 bps | 11 |
4800 bps | 12 |
7200 bps | 13 |
9600 bps | 14 |
Set the following parameters on the PC
Serial port tab
Machine name | Bosch alpha 3 |
Serial port | COM2 (or any free COM port) |
Baud | 1200 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start:
Program end:
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Bosch CC220
Bosch CC320
Bridgeport - Boss 3
Bridgeport - Boss 4
Bridgeport - Boss 5
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.