Schneider Electric (iEM3000) logging - MODBUS registers map


The following data can be automatically logger 24x7 to a database, CSV files or Excel with the help of the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software.

MODBUS offset
Description
Units
Data type
7274
Digital input control mode
 
word
8905
Digital input status (only bit 1 is used): bit
 
word
9673
Digital output control mode status
 
word
3000
I1: phase 1 current
A
single
3002
I2: phase 2 current
A
single
3004
I3: phase 3 current
A
single
3010
Currentavg
A
single
3020
Voltage L1 L2
V
single
3022
Voltage L2 L3
V
single
3024
Voltage L3 L1
V
single
3026
Voltage ll avg
V
single
3028
Voltage L1 N
V
single
3030
Voltage L2 N
V
single
3032
Voltage L3 N
V
single
3036
Voltage ln avg
V
single
3054
Active power phase 1
kW
single
3056
Active power phase 2
kW
single
3058
Active power phase 3
kW
single
3060
Total active power
kW
single
3068
Total reactive power not applicable for iem3150 / iem3250 / iem3350
kVAR
single
3076
Total apparent power not applicable for iem3150 / iem3250 / iem3350
kVA
single
3084
Total power factor: 1 < pf
 
single
3110
Frequency
Hz
single
4191
Multitariffs energy active rate 0: multi tariff disabled 1 to 4: rate A to rate D not applicable for iem3150 / iem3250 / iem3350 note: you can only set the tariff using this method if the tariff mode is set to by communication
 
word
3204
Total active energy import
Wh
int64
3208
Total active energy export not applicable for iem3150 / iem3250 / iem3350
Wh
int64
3220
Total reactive energy import not applicable for iem3150 / iem3250 / iem3350
VARh
int64
3224
Total reactive energy export not applicable for iem3150 / iem3250 / iem3350
VARh
int64
3256
Partial active energy import
Wh
int64
3272
Partial reactive energy import not applicable for iem3150 / iem3250 / iem3350
VARh
int64
3518
Active energy import phase1
Wh
int64
3522
Active energy import phase 2
Wh
int64
3526
Active energy import phase 3
Wh
int64
3558
Input metering accumulation not applicable for iem3150 / iem3250 / iem3350
Unit
int64
3701
Demand method
 
word
3702
Demand interval duration
Minute
word
3766
Active power demand
kW
single
3770
Active power peak demand
kW
single
3782
Reactive power demand
kVAR
single
3786
Reactive power peak demand
kVAR
single
3798
Apparent power demand
kVA
single
3802
Apparent power peak demand
kVA
single
3814
Current I1 demand
A
single
3818
Current I1 peak demand
A
single
3830
Current I2 demand
A
single
3834
Current I2 peak demand
A
single
3846
Current I3 demand
A
single
3850
Current I3 peak demand
A
single
3878
Current avg demand
A
single
3882
Current avg peak demand
A
single
There are more MODBUS items for this device. Please download the program to discover all registers.