bg

Epsolar (LS-B Series) data logging - MODBUS registers map


The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These tools provide continuous and reliable Epsolar (LS-B Series) data logging and read.

MODBUS offset
Description
Units
Data type
12288
Charging equipment rated input voltage
 
word
12289
Charging equipment rated input current
A
word
12290
Charging equipment rated input power
 
dword
12292
Charging equipment rated output voltage
V
word
12293
Charging equipment rated output current
A
word
12294
Charging equipment rated output power
 
word
12295
Charging equipment rated output power
 
word
12296
Charging mode
 
word
12302
Rated output current of load
A
word
12544
Charging equipment input voltage
V
word
12545
Charging equipment input current
A
word
12546
Charging equipment input power
 
dword
12548
Charging equipment output voltage
 
word
12549
Charging equipment output current
A
word
12550
Charging equipment output power
 
dword
12556
Disharging equipment output voltage
V
word
12557
Disharging equipment output current
A
word
12558
Disharging equipment output power
 
word
12559
Disharging equipment output power
 
word
12560
Battery temperature
degree Celsius
word
12561
Temperature inside equipment
degree Celsius
word
12562
Power components temperature
degree Celsius
word
12570
Battery soc
 
word
12571
Remote battery temperature
degree Celsius
word
12573
Battery's real rated power
 
word
13056
Maximum input volt (pv) today
 
word
13057
Minimum input volt (pv) today
V
word
13058
Maximum battery volt today
V
word
13059
Minimum battery volt today
V
word
13060
Consumed energy today
KWH
dword
13062
Consumed energy this month
 
dword
13064
Consumed energy this year
 
dword
13066
Total consumed energy
 
dword
13068
Generated energy today
 
dword
13070
Generated energy this month
 
dword
13072
Generated energy this year
 
dword
13074
Total generated energy
KWH
dword
13076
Carbon dioxide reduction
Ton
dword
13083
Battery current
A
dword
13085
Battery temp
degree Celsius
word