ENTES (MPR7 Series) data logging - MODBUS registers map


The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These tools provide continuous and reliable ENTES (MPR7 Series) data logging and record.

MODBUS offset
Description
Units
Data type
2
L2 phase voltage
Vot
dword
4
L3 phase voltage
Vot
dword
6
L1 phase current
Amper
dword
8
L2 phase current
Amper
dword
10
L3 phase current
Amper
dword
12
Neutral current
Amper
dword
14
L1 L2 phase phase voltage
Vot
dword
16
L2 L3 phase phase voltage
Vot
dword
18
L3 L1 phase phase voltage
Vot
dword
20
L1 phase active power
Watt
integer
22
L2 phase active power
Watt
integer
24
L3 phase active power
Watt
integer
26
L1 phase reactive power
Var
integer
28
L2 phase reactive power
Var
integer
30
L3 phase reactive power
Var
integer
32
L1 phase apparent power
VA
dword
34
L2 phase apparent power
VA
dword
36
L3 phase apparent power
VA
dword
38
L1 phase cos
 
integer
40
L2 phase cos
 
integer
42
L3 phase cos
 
integer
44
Total import active power
Watt
integer
46
Total export active power
Watt
integer
48
Total inductive reactive power
Var
integer
50
Total capacitive reactive power
Var
integer
52
Total apparent power
VA
dword
54
Average inductive cos
 
integer
56
Average capacitive cos
 
integer
58
Frequency
Hz
dword
88
Import active energy 1
Wh
dword
92
Export active energy 1
Wh
dword
96
Inductive reactive energy 1
VArh
dword
100
Capacitive reactive energy 1
VArh
dword
104
Import active energy 2
Wh
dword
108
Export active energy 2
Wh
dword
112
Inductive reactive energy 2
VArh
dword
116
Capacitive reactive energy 2
VArh
dword
118
L1 phase min. voltage
Vot
dword
120
L2 phase min. voltage
Vot
dword
122
L3 phase min. voltage
Vot
dword
124
L1 L2 phase phase min. voltage
Vot
dword
126
L2 L3 phase phase min. voltage
Vot
dword
128
L3 L1 phase phase min. voltage
Vot
dword
130
L1 phase min. current
Amper
dword
132
L2 phase min. current
Amper
dword
134
L3 phase min. current
Amper
dword
136
L1 phase min. active power
Watt
integer
138
L2 phase min. active power
Watt
integer
140
L3 phase min. active power
Watt
integer
142
L1 phase min. reactive power
Var
integer
There are more MODBUS items for this device. Please download the program to discover all registers.