Socomec MODBUS logger. Registers Map


The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These tools provide continuous and reliable Socomec logger and log.

Socomec (Countis E03) - Mapping

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50520
Simple voltage: V1
 
dword
50528
Current: I1
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50556
Apparent power phase 1: S1
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50946
Total positive active energy (no resetable): ea+
 
dword
36868
Active energy
 
dword

Socomec (Countis E04) - MODBUS Registers

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50520
Simple voltage: V1
 
dword
50528
Current: I1
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50556
Apparent power phase 1: S1
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50946
Total positive active energy (no resetable): ea+
 
dword
36868
Active energy
 
dword

Socomec (Countis E13) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50520
Simple voltage: V1
 
dword
50528
Current: I1
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50556
Apparent power phase 1: S1
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
50786
Partial negative active energy: ea-
 
dword
50946
Total positive active energy (no resetable): ea+
 
dword
50948
Total positive reactive energy (no resetable): er +
 
dword
50952
Total negative active energy (no resetable): ea-
 
dword
50956
Partial positive active energy: ea+
 
dword
50958
Partial positive reactive energy: er +
 
dword
50962
Partial negative active energy: ea-
 
dword
51281
Phase to phase voltage: U12
 
word
51282
Phase to phase voltage: U23
 
word
51283
Phase to phase voltage: U31
 
word
51284
Simple voltage: V1
 
word
51285
Simple voltage: V2
 
word
51286
Simple voltage: V3
 
word
51295
Power factor: -: leading and +: lagging: PF
 
smallint
51311
Total positive active energy (no resetable): ea+
 
word
51312
Total positive reactive energy (no resetable): er +
 
word
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E14) - MODBUS Registers

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50520
Simple voltage: V1
 
dword
50528
Current: I1
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50556
Apparent power phase 1: S1
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
50786
Partial negative active energy: ea-
 
dword
50946
Total positive active energy (no resetable): ea+
 
dword
50948
Total positive reactive energy (no resetable): er +
 
dword
50952
Total negative active energy (no resetable): ea-
 
dword
50956
Partial positive active energy: ea+
 
dword
50958
Partial positive reactive energy: er +
 
dword
50962
Partial negative active energy: ea-
 
dword
51281
Phase to phase voltage: U12
 
word
51282
Phase to phase voltage: U23
 
word
51283
Phase to phase voltage: U31
 
word
51284
Simple voltage: V1
 
word
51285
Simple voltage: V2
 
word
51286
Simple voltage: V3
 
word
51295
Power factor: -: leading and +: lagging: PF
 
smallint
51311
Total positive active energy (no resetable): ea+
 
word
51312
Total positive reactive energy (no resetable): er +
 
word
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E23) - MODBUS Registers

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50552
Reactive power phase 2 +/-: Q2
 
integer
50554
Reactive power phase 3 +/-: Q3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
50566
Power factor phase 3 -: leading and +: lagging: PF3
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E24) - Mapping

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50552
Reactive power phase 2 +/-: Q2
 
integer
50554
Reactive power phase 3 +/-: Q3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
50566
Power factor phase 3 -: leading and +: lagging: PF3
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E33, Countis E43) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50030
Product VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
38912
Communication board version (Major)
 
word
38913
Communication board version (Minor)
 
word
38914
Communication board version (Revision)
 
word
38915
Communication board version (Build)
 
word
38919
Communication board VLO
 
string(8)
57346
Current transformer primary
 
word
57355
Synchronisation top for P+/- Q+/-: time in seconds ( 1mn, 5mn, 8mn, 10mn, 15mn, 20mn, 30mn, 60mn)
 
word
57602
Year
 
word
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50526
Frequency: F
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50552
Reactive power phase 2 +/-: Q2
 
integer
50554
Reactive power phase 3 +/-: Q3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
50566
Power factor phase 3 -: leading and +: lagging: PF3
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E34, Countis E44) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50030
Product VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
38912
Communication board version (Major)
 
word
38913
Communication board version (Minor)
 
word
38914
Communication board version (Revision)
 
word
38915
Communication board version (Build)
 
word
38919
Communication board VLO
 
string(8)
57346
Current transformer primary
 
word
57355
Synchronisation top for P+/- Q+/-: time in seconds ( 1mn, 5mn, 8mn, 10mn, 15mn, 20mn, 30mn, 60mn)
 
word
57602
Year
 
word
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50526
Frequency: F
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50534
Neutral current: in
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50552
Reactive power phase 2 +/-: Q2
 
integer
50554
Reactive power phase 3 +/-: Q3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
50566
Power factor phase 3 -: leading and +: lagging: PF3
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
50780
Partial positive active energy: ea+
 
dword
50782
Partial positive reactive energy: er +
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E50 E53 E50R E53R) - Mapping

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
57346
Current transformer primary
 
word
50512
Hour meter
 
dword
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50536
Active power +/-: P
 
integer
50538
Reactive power +/-: Q
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50550
Reactive power phase 1 +/-: Q1
 
integer
50552
Reactive power phase 2 +/-: Q2
 
integer
50554
Reactive power phase 3 +/-: Q3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
50566
Power factor phase 3 -: leading and +: lagging: PF3
 
integer
50770
Total positive active energy (no resetable): ea+
 
dword
50772
Total positive reactive energy (no resetable): er +
 
dword
50774
Total apparent energy (no resetable): es
 
dword
50776
Total negative active energy (no resetable): ea-
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis E63) - Mapping

MODBUS offset
Description
Units
Data type
50000
Product name
 
string(8)
50004
Product order ID (Countis:100, protection:200, atys:300, diris:400)
 
word
50005
Product ID
 
word
50007
Product software version
 
word
50018
Product version (Major)
 
word
50019
Product version (Minor)
 
word
50020
Product version (Revision)
 
word
50021
Product version (Build)
 
word
50025
Software technical base version (Major)
 
word
50026
Software technical base version (Minor)
 
word
50027
Software technical base version (Revision)
 
word
50028
Customization version (Major)
 
word
50029
Customization version (Minor)
 
word
50030
Product VLO
 
string(8)
50034
Customization VLO
 
string(8)
50038
Software technical base VLO
 
string(8)
50042
Vendor name
 
string(16)
50050
Product name
 
string(16)
50058
Extended name
 
string(16)
38912
Communication board version (Major)
 
word
38913
Communication board version (Minor)
 
word
38914
Communication board version (Revision)
 
word
38915
Communication board version (Build)
 
word
38919
Communication board VLO
 
string(8)
57346
Current transformer primary
 
word
57355
Synchronisation top for P+/- Q+/-: time in seconds ( 2mn, 5mn, 8mn, 10mn, 15mn, 20mn, 30mn, 60mn)
 
word
57602
Year
 
word
50770
Total positive active energy (no resetable): ea+
 
dword
50780
Partial positive active energy: ea+
 
dword
50514
Phase to phase voltage: U12
 
dword
50516
Phase to phase voltage: U23
 
dword
50518
Phase to phase voltage: U31
 
dword
50520
Simple voltage: V1
 
dword
50522
Simple voltage: V2
 
dword
50524
Simple voltage: V3
 
dword
50526
Frequency: F
 
dword
50528
Current: I1
 
dword
50530
Current: I2
 
dword
50532
Current: I3
 
dword
50536
Active power +/-: P
 
integer
50540
Apparent power: S
 
dword
50542
Power factor: -: leading et +: lagging: PF
 
integer
50544
Active power phase 1 +/-: P1
 
integer
50546
Active power phase 2 +/-: P2
 
integer
50548
Active power phase 3 +/-: P3
 
integer
50556
Apparent power phase 1: S1
 
dword
50558
Apparent power phase 2: S2
 
dword
50560
Apparent power phase 3: S3
 
dword
50562
Power factor phase 1 -: leading and +: lagging: PF1
 
integer
50564
Power factor phase 2 -: leading and +: lagging: PF2
 
integer
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis ECI2) - MODBUS Registers

MODBUS offset
Description
Units
Data type
37072
Label of custom unit
 
string(4)
45058
Save context count
 
dword
40192
Name
 
string(10)
40197
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40198
Operand1
 
word
40199
Operand2
 
word
40200
Severity: 0: none 1: information 2: warning 3: default
 
word
40201
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40202
Combination mode: 0: OR 1: AND
 
word
40203
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40204
AnaValHyst
 
word
40205
AnaValLow
 
dword
40207
AnaValHigh
 
dword
40209
Name
 
string(10)
40214
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40215
Operand1
 
word
40216
Operand2
 
word
40217
Severity: 0: none 1: information 2: warning 3: default
 
word
40218
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40219
Combination mode: 0: OR 1: AND
 
word
40220
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40221
AnaValHyst
 
word
40222
AnaValLow
 
dword
40224
AnaValHigh
 
dword
40226
Name
 
string(10)
40231
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40232
Operand1
 
word
40233
Operand2
 
word
40234
Severity: 0: none 1: information 2: warning 3: default
 
word
40235
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40236
Combination mode: 0: OR 1: AND
 
word
40237
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40238
AnaValHyst
 
word
40239
AnaValLow
 
dword
40241
AnaValHigh
 
dword
40243
Name
 
string(10)
40248
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40249
Operand1
 
word
40250
Operand2
 
word
40251
Severity: 0: none 1: information 2: warning 3: default
 
word
40252
Logical mode: 0: low state 1: high state 2: falling edge 3: rising edge 4: both falling and rising edge
 
word
40253
Combination mode: 0: OR 1: AND
 
word
40254
Analogical value comparison type: 0: low and high comparison 1: only high 2: only low 3: match with high level on rising 4: match with low level on falling
 
word
40255
AnaValHyst
 
word
40256
AnaValLow
 
dword
40258
AnaValHigh
 
dword
40260
Name
 
string(10)
40265
Mode: 0: disabled 1: logical state 2: analogical value 3: combination
 
word
40266
Operand1
 
word
40267
Operand2
 
word
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Countis ECI3) - MODBUS Registers Map

MODBUS offset
Description
Units
Data type
38020
Input 1 absolute value
 
dword
38023
Input 2 absolute value
 
dword
38027
Input 1 value for 0mA
 
dword
38029
Input 1 value for 20mA
 
dword
38033
Input 2 value for 0mA
 
dword
38035
Input 2 value for 20mA
 
dword
39170
Integration period
 
word
39172
Numerator rate
 
word
39173
Denominator rate
 
word
39177
Value without CT*VT rate
 
word
39314
Integration period
 
word
39316
Numerator rate
 
word
39317
Denominator rate
 
word
39321
Value without CT*VT rate
 
word
39936
Name
 
string(10)
39941
Mode: 0: disabled 1: 0-20mA 2: 4-20mA
 
word
39942
Unit: 0: A 1: V 2: W 3: kW 4: VAR 5: kVAR 6: VA 7: kVA 8: C 9: F 10: mbar 11: bar 12: custom unit
 
word
39943
Integration time
 
word
39944
Synchro type: 0: RTC 1: external
 
word
39945
X_Pt1
 
word
39946
Y_Pt1
 
dword
39948
X_Pt2
 
word
39949
Y_Pt2
 
dword
39951
X_Pt3
 
word
39952
Y_Pt3
 
dword
39954
X_Pt4
 
word
39955
Y_Pt4
 
dword
39957
X_Pt5
 
word
39958
Y_Pt5
 
dword
39960
Name
 
string(10)
39965
Mode: 0: disabled 1: 0-20mA 2: 4-20mA
 
word
39966
Unit: 0: A 1: V 2: W 3: kW 4: VAR 5: kVAR 6: VA 7: kVA 8: C 9: F 10: mbar 11: bar 12: custom unit
 
word
39967
Integration time
 
word
39968
Synchro type: 0: RTC 1: external
 
word
39969
X_Pt1
 
word
39970
Y_Pt1
 
dword
39972
X_Pt2
 
word
39973
Y_Pt2
 
dword
39975
X_Pt3
 
word
39976
Y_Pt3
 
dword
39978
X_Pt4
 
word
39979
Y_Pt4
 
dword
39981
X_Pt5
 
word
39982
Y_Pt5
 
dword
39869
Load curves base integration time
 
word
39872
External synchro type: 0: disabled 1: input 7 2: COM
 
word
39873
External synchro period
 
word
39874
Currency unit: 0: euro 1: US dollar 2: GB pound 3: yuan 4: other
 
word
37072
Label of custom unit
 
string(4)
45058
Save context count
 
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (DIRIS I31) - MODBUS Registers

MODBUS offset
Description
Units
Data type
18433
Inst. Measurement. Load #1. Date of last instance
s
dword
18435
Inst. Measurement. Load #1. Integration time
s
word
18442
Inst. Measurement. Load #1. Frequency
Hz
dword
18444
Inst. Measurement. Load #1. Ph N voltage : V1
V
dword
18446
Inst. Measurement. Load #1. Ph N voltage : V2
V
dword
18448
Inst. Measurement. Load #1. Ph N voltage : V3
V
dword
18452
Inst. Measurement. Load #1. Ph ph voltage : U12
V
dword
18454
Inst. Measurement. Load #1. Ph ph voltage : U23
V
dword
18456
Inst. Measurement. Load #1. Ph ph voltage : U31
V
dword
18458
Inst. Measurement. Load #1. Current : I1
A
dword
18460
Inst. Measurement. Load #1. Current : I2
A
dword
18462
Inst. Measurement. Load #1. Current : I3
A
dword
18464
Inst. Measurement. Load #1. Current : in
A
dword
18474
Inst. Measurement. Load #1. Snom
VA
dword
18476
Inst. Measurement. Load #1. Total active power
W
integer
18478
Inst. Measurement. Load #1. Total reactive power
var
integer
18480
Inst. Measurement. Load #1. Total lagging reactive power
var
integer
18482
Inst. Measurement. Load #1. Total leading reactive power
var
integer
18484
Inst. Measurement. Load #1. Total apparent power
VA
dword
18486
Inst. Measurement. Load #1. Total power factor
-
smallint
18487
Inst. Measurement. Load #1. Total power factor type
 
byte
20481
Inst. Measurement. Load #2. Date of last instance
s
dword
20483
Inst. Measurement. Load #2. Integration time
s
word
20490
Inst. Measurement. Load #2. Frequency
Hz
dword
20492
Inst. Measurement. Load #2. Ph N voltage : V1
V
dword
20494
Inst. Measurement. Load #2. Ph N voltage : V2
V
dword
20496
Inst. Measurement. Load #2. Ph N voltage : V3
V
dword
20500
Inst. Measurement. Load #2. Ph ph voltage : U12
V
dword
20502
Inst. Measurement. Load #2. Ph ph voltage : U23
V
dword
20504
Inst. Measurement. Load #2. Ph ph voltage : U31
V
dword
20506
Inst. Measurement. Load #2. Current : I1
A
dword
20508
Inst. Measurement. Load #2. Current : I2
A
dword
20510
Inst. Measurement. Load #2. Current : I3
A
dword
20512
Inst. Measurement. Load #2. Current : in
A
dword
20522
Inst. Measurement. Load #2. Snom
VA
dword
20524
Inst. Measurement. Load #2. Total active power
W
integer
20526
Inst. Measurement. Load #2. Total reactive power
var
integer
20528
Inst. Measurement. Load #2. Total lagging reactive power
var
integer
20530
Inst. Measurement. Load #2. Total leading reactive power
var
integer
20532
Inst. Measurement. Load #2. Total apparent power
VA
dword
20534
Inst. Measurement. Load #2. Total power factor
-
smallint
20535
Inst. Measurement. Load #2. Total power factor type
 
byte
22529
Inst. Measurement. Load #3. Date of last instance
s
dword
22531
Inst. Measurement. Load #3. Integration time
s
word
22538
Inst. Measurement. Load #3. Frequency
Hz
dword
22540
Inst. Measurement. Load #3. Ph N voltage : V1
V
dword
22542
Inst. Measurement. Load #3. Ph N voltage : V2
V
dword
22544
Inst. Measurement. Load #3. Ph N voltage : V3
V
dword
22548
Inst. Measurement. Load #3. Ph ph voltage : U12
V
dword
22550
Inst. Measurement. Load #3. Ph ph voltage : U23
V
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (DIRIS U10) - MODBUS Registers

MODBUS offset
Description
Units
Data type
36864
Inst. Measurement. Network. Date of last instance
s
dword
36866
Inst. Measurement. Network. Integration time
s
word
36867
Inst. Measurement. Network. Frequency
Hz
dword
36869
Inst. Measurement. Network. Ph N voltage : V1
V
dword
36871
Inst. Measurement. Network. Ph N voltage : V2
V
dword
36873
Inst. Measurement. Network. Ph N voltage : V3
V
dword
36875
Inst. Measurement. Network. Ph ph voltage : U12
V
dword
36877
Inst. Measurement. Network. Ph ph voltage : U23
V
dword
36879
Inst. Measurement. Network. Ph ph voltage : U31
V
dword

Socomec (DIRIS U20) - Mapping

MODBUS offset
Description
Units
Data type
36864
Inst. Measurement. Network. Date of last instance
s
dword
36866
Inst. Measurement. Network. Integration time
s
word
36867
Inst. Measurement. Network. Frequency
Hz
dword
36869
Inst. Measurement. Network. Ph N voltage : V1
V
dword
36871
Inst. Measurement. Network. Ph N voltage : V2
V
dword
36873
Inst. Measurement. Network. Ph N voltage : V3
V
dword
36875
Inst. Measurement. Network. Ph ph voltage : U12
V
dword
36877
Inst. Measurement. Network. Ph ph voltage : U23
V
dword
36879
Inst. Measurement. Network. Ph ph voltage : U31
V
dword
37120
Inst. Fundamental measurement. Network. Date of last instance
s
dword
37122
Inst. Fundamental measurement. Network. Integration time
s
word
37123
Inst. Fundamental measurement. Network. Ph N voltage: v1h1
V
dword
37125
Inst. Fundamental measurement. Network. Ph N voltage: v2h1
V
dword
37127
Inst. Fundamental measurement. Network. Ph N voltage: v3h1
V
dword
37129
Inst. Fundamental measurement. Network. Ph N voltage: vnh1
V
dword
37131
Inst. Fundamental measurement. Network. Ph N voltage phase: phv1h1
?
smallint
37132
Inst. Fundamental measurement. Network. Ph N voltage phase: phv2h1
?
smallint
37133
Inst. Fundamental measurement. Network. Ph N voltage phase: phv3h1
?
smallint
37134
Inst. Fundamental measurement. Network. Ph N voltage phase: phvnh1
?
smallint
37135
Inst. Fundamental measurement. Network. Ph ph voltage: u12h1
V
dword
37137
Inst. Fundamental measurement. Network. Ph ph voltage: u23h1
V
dword
37139
Inst. Fundamental measurement. Network. Ph ph voltage: u31h1
V
dword
37141
Inst. Fundamental measurement. Network. Ph ph voltage phase: phu12h1
?
smallint
37142
Inst. Fundamental measurement. Network. Ph ph voltage phase: phu23h1
?
smallint
37143
Inst. Fundamental measurement. Network. Ph ph voltage phase: phu31h1
?
smallint
37144
Inst. Fundamental measurement. Network. Ph N voltage total harmonic distortion : thd V1
%
word
37145
Inst. Fundamental measurement. Network. Ph N voltage total harmonic distortion : thd V2
%
word
37146
Inst. Fundamental measurement. Network. Ph N voltage total harmonic distortion : thd V3
%
word
37147
Inst. Fundamental measurement. Network. Ph ph voltage total harmonic distortion : thd U12
%
word
37148
Inst. Fundamental measurement. Network. Ph ph voltage total harmonic distortion : thd U23
%
word
37149
Inst. Fundamental measurement. Network. Ph ph voltage total harmonic distortion : thd U31
%
word

Socomec (DIRIS U30) - Mapping

MODBUS offset
Description
Units
Data type
36864
Inst. Measurement. Network. Date of last instance
s
dword
36866
Inst. Measurement. Network. Integration time
s
word
36867
Inst. Measurement. Network. System ph N voltage
V
dword
36869
Inst. Measurement. Network. System ph ph voltage
V
dword
36871
Inst. Measurement. Network. Frequency
Hz
dword
36873
Inst. Measurement. Network. Ph N voltage : V1
V
dword
36875
Inst. Measurement. Network. Ph N voltage : V2
V
dword
36877
Inst. Measurement. Network. Ph N voltage : V3
V
dword
36879
Inst. Measurement. Network. Ph N voltage : vn
V
dword
36881
Inst. Measurement. Network. Ph ph voltage : U12
V
dword
36883
Inst. Measurement. Network. Ph ph voltage : U23
V
dword
36885
Inst. Measurement. Network. Ph ph voltage : U31
V
dword
36887
Inst. Measurement. Network. Vdir
V
dword
36889
Inst. Measurement. Network. Vinv
V
dword
36891
Inst. Measurement. Network. Vhom
V
dword
36893
Inst. Measurement. Network. Vnb
%
word
36894
Inst. Measurement. Network. Udir
V
dword
36896
Inst. Measurement. Network. Uinv
V
dword
36898
Inst. Measurement. Network. Unb
%
word
36899
Inst. Measurement. Network. Vnba
%
word
36900
Inst. Measurement. Network. Unba
%
word
36992
Avg. Measurement. Network. Date of last instance
s
dword
36994
Avg. Measurement. Network. Integration time
s
word
36995
Avg. Measurement. Network. System ph N voltage
V
dword
36997
Avg. Measurement. Network. System ph ph voltage
V
dword
36999
Avg. Measurement. Network. Frequency
Hz
dword
37001
Avg. Measurement. Network. Ph N voltage : V1
V
dword
37003
Avg. Measurement. Network. Ph N voltage : V2
V
dword
37005
Avg. Measurement. Network. Ph N voltage : V3
V
dword
37007
Avg. Measurement. Network. Ph N voltage : vn
V
dword
37009
Avg. Measurement. Network. Ph ph voltage : U12
V
dword
37011
Avg. Measurement. Network. Ph ph voltage : U23
V
dword
37013
Avg. Measurement. Network. Ph ph voltage : U31
V
dword
37015
Avg. Measurement. Network. Vdir
V
dword
37017
Avg. Measurement. Network. Vinv
V
dword
37019
Avg. Measurement. Network. Vhom
V
dword
37021
Avg. Measurement. Network. Vnb
%
word
37022
Avg. Measurement. Network. Udir
V
dword
37024
Avg. Measurement. Network. Uinv
V
dword
37026
Avg. Measurement. Network. Unb
%
word
37027
Avg. Measurement. Network. Vnba
%
word
37028
Avg. Measurement. Network. Unba
%
word
37120
Inst. Fundamental measurement. Network. Date of last instance
s
dword
37122
Inst. Fundamental measurement. Network. Integration time
s
word
37123
Inst. Fundamental measurement. Network. Ph N voltage: v1h1
V
dword
37125
Inst. Fundamental measurement. Network. Ph N voltage: v2h1
V
dword
37127
Inst. Fundamental measurement. Network. Ph N voltage: v3h1
V
dword
37129
Inst. Fundamental measurement. Network. Ph N voltage: vnh1
V
dword
37131
Inst. Fundamental measurement. Network. Ph N voltage phase: phv1h1
?
smallint
37132
Inst. Fundamental measurement. Network. Ph N voltage phase: phv2h1
?
smallint
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (DIRIS,D30,D50,D70) - Mapping

MODBUS offset
Description
Units
Data type
18433
Inst. Measurement. Load #1. Date of last instance
s
dword
18435
Inst. Measurement. Load #1. Integration time
s
word
18442
Inst. Measurement. Load #1. Frequency
Hz
dword
18444
Inst. Measurement. Load #1. Ph N voltage : V1
V
dword
18446
Inst. Measurement. Load #1. Ph N voltage : V2
V
dword
18448
Inst. Measurement. Load #1. Ph N voltage : V3
V
dword
18452
Inst. Measurement. Load #1. Ph ph voltage : U12
V
dword
18454
Inst. Measurement. Load #1. Ph ph voltage : U23
V
dword
18456
Inst. Measurement. Load #1. Ph ph voltage : U31
V
dword
18458
Inst. Measurement. Load #1. Current : I1
A
dword
18460
Inst. Measurement. Load #1. Current : I2
A
dword
18462
Inst. Measurement. Load #1. Current : I3
A
dword
18464
Inst. Measurement. Load #1. Current : in
A
dword
18474
Inst. Measurement. Load #1. Snom
VA
dword
18476
Inst. Measurement. Load #1. Total active power
W
integer
18478
Inst. Measurement. Load #1. Total reactive power
var
integer
18480
Inst. Measurement. Load #1. Total lagging reactive power
var
integer
18482
Inst. Measurement. Load #1. Total leading reactive power
var
integer
18484
Inst. Measurement. Load #1. Total apparent power
VA
dword
18486
Inst. Measurement. Load #1. Total power factor
 
smallint
18487
Inst. Measurement. Load #1. Total power factor type
 
byte
20481
Inst. Measurement. Load #2. Date of last instance
s
dword
20483
Inst. Measurement. Load #2. Integration time
s
word
20490
Inst. Measurement. Load #2. Frequency
Hz
dword
20492
Inst. Measurement. Load #2. Ph N voltage : V1
V
dword
20494
Inst. Measurement. Load #2. Ph N voltage : V2
V
dword
20496
Inst. Measurement. Load #2. Ph N voltage : V3
V
dword
20500
Inst. Measurement. Load #2. Ph ph voltage : U12
V
dword
20502
Inst. Measurement. Load #2. Ph ph voltage : U23
V
dword
20504
Inst. Measurement. Load #2. Ph ph voltage : U31
V
dword
20506
Inst. Measurement. Load #2. Current : I1
A
dword
20508
Inst. Measurement. Load #2. Current : I2
A
dword
20510
Inst. Measurement. Load #2. Current : I3
A
dword
20512
Inst. Measurement. Load #2. Current : in
A
dword
20522
Inst. Measurement. Load #2. Snom
VA
dword
20524
Inst. Measurement. Load #2. Total active power
W
integer
20526
Inst. Measurement. Load #2. Total reactive power
var
integer
20528
Inst. Measurement. Load #2. Total lagging reactive power
var
integer
20530
Inst. Measurement. Load #2. Total leading reactive power
var
integer
20532
Inst. Measurement. Load #2. Total apparent power
VA
dword
20534
Inst. Measurement. Load #2. Total power factor
 
smallint
20535
Inst. Measurement. Load #2. Total power factor type
 
byte
22529
Inst. Measurement. Load #3. Date of last instance
s
dword
22531
Inst. Measurement. Load #3. Integration time
s
word
22538
Inst. Measurement. Load #3. Frequency
Hz
dword
22540
Inst. Measurement. Load #3. Ph N voltage : V1
V
dword
22542
Inst. Measurement. Load #3. Ph N voltage : V2
V
dword
22544
Inst. Measurement. Load #3. Ph N voltage : V3
V
dword
22548
Inst. Measurement. Load #3. Ph ph voltage : U12
V
dword
22550
Inst. Measurement. Load #3. Ph ph voltage : U23
V
dword
There are more MODBUS items for this device. Please download the program to discover all registers.

Socomec (Multis L20, Multis L40) - MODBUS Registers

MODBUS offset
Description
Units
Data type
2
Voltage, L2
V
dword
4
Voltage, L3
V
dword
6
Current, L1
A
dword
8
Current, L2
A
dword
10
Current, L3
A
dword
12
Current, L-N
A
dword
14
Voltage, L1-L2
V
dword
16
Voltage, L2-L3
V
dword
18
Voltage, L1-L3
V
dword
20
Active power, L1
W
integer
22
Active power, L2
W
integer
24
Active power, L3
W
integer
26
Reactive power, L1
Var
integer
28
Reactive power, L2
Var
integer
30
Reactive power, L3
Var
integer
32
Apparent power, L1
Var
dword
34
Apparent power, L2
Var
dword
36
Apparent power, L3
Var
dword
38
Power factor, L1
 
integer
40
Power factor, L1
 
integer
42
Power factor, L1
 
integer
44
Total import active power
W
integer
46
Total export active power
W
integer
48
Total inductive reactive power
Var
integer
50
Total capacitive reactive power
Var
integer
52
Total apparent power
VA
dword
54
Average inductive CosF
Var
integer
56
Average capacitive CosF
Var
integer
58
Frequency
Hz
integer
60
Voltage angle, L1
Deg
dword
62
Voltage angle, L2
Deg
dword
64
Voltage angle, L3
Deg
dword
66
Current angle, L1
Deg
dword
68
Current angle, L2
Deg
dword
70
Current angle, L3
Deg
dword
84
Digital inputs
 
dword
86
Import active energy 1
Wh
int64
90
Export active energy 1
Wh
int64
94
Inductive reactive energy 1
VArh
int64
98
Capacitive reactive energy 1
VArh
int64
102
Import active energy 2
Wh
int64
106
Export active energy 2
Wh
int64
110
Inductive reactive energy 2
VArh
int64
114
Capacitive reactive energy 2
VArh
int64
118
Voltage, min, L1
V
dword
120
Voltage, min, L2
V
dword
122
Voltage, min, L3
V
dword
124
Voltage, min, L1-L2
V
dword
126
Voltage, min, L2-L3
V
dword
128
Voltage, min, L3-L1
V
dword
There are more MODBUS items for this device. Please download the program to discover all registers.