Electrex MODBUS logger. Registers Map
The data can be automatically logged 24/7 into a database, CSV files, or Excel spreadsheets using the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP) software. These tools provide continuous and reliable Electrex logger and log.
Electrex (Est) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
16
Active Power, Maximum Demand
double
18
Reactive Power, Maximum Demand
double
20
Active Energy (total)
double
23
Reactive Energy (total)
double
Electrex (Exa) - Mapping
MODBUS offset
Description
Units
Data type
200
Phase to neutral voltage, thd
%
single
202
Phase to neutral voltage, thd
%
single
204
Phase to neutral voltage, thd
%
single
206
Phase to phase voltage, thd
%
single
208
Phase to phase voltage, thd
%
single
210
Phase to phase voltage, thd
%
single
212
Phase current, thd
%
single
214
Phase current, thd
%
single
216
Phase current, thd
%
single
218
Frequency of u1n
Hz
single
220
Phase to neutral voltage, rms amplitude
V
single
222
Phase to neutral voltage, rms amplitude
V
single
224
Phase to neutral voltage, rms amplitude
V
single
226
Phase to phase voltage, rms amplitude
V
single
228
Phase to phase voltage, rms amplitude
V
single
230
Phase to phase voltage, rms amplitude
V
single
232
Phase current, rms amplitude
A
single
234
Phase current, rms amplitude
A
single
236
Phase current, rms amplitude
A
single
238
Neutral current, rms amplitude
A
single
240
Phase active power (imp/ exp)
W
single
242
Phase active power (imp/ exp)
W
single
244
Phase active power (imp/ exp)
W
single
246
Phase reactive power (imp/ exp)
var
single
248
Phase reactive power (imp/ exp)
var
single
250
Phase reactive power (imp/ exp)
var
single
252
Phase apparent power
VA
single
254
Phase apparent power
VA
single
256
Phase apparent power
VA
single
258
Phase power factor (imp/ exp)
-
single
260
Phase power factor (imp/ exp)
-
single
262
Phase power factor (imp/ exp)
-
single
264
Phase to neutral voltage, mean thd
%
single
266
Phase to phase voltage, mean thd
%
single
268
Phase current, mean thd
%
single
270
Phase to neutral voltage, mean rms amplitude
V
single
272
Phase to phase voltage, mean rms amplitude
V
single
274
Three phase current, rms amplitude
A
single
276
Total active power (imp/ exp)
W
single
278
Total reactive power (imp/ exp)
var
single
280
Total apparent power
VA
single
282
Total power factor (imp/ exp)
-
single
332
Phase current, rms amplitude, avg
A
single
334
Phase current, rms amplitude, avg
A
single
336
Phase current, rms amplitude, avg
A
single
344
Total imported active power, avg
W
single
346
Total imported inductive power, avg
var
single
348
Total imported capacitive power, avg
var
single
350
Total imported apparent power, avg
VA
single
352
Total exported active power, avg
W
single
There are more MODBUS items for this device. Please download the program to discover all registers.
Electrex (Femto) - Mapping
MODBUS offset
Description
Units
Data type
200
Phase to neutral voltage, thd
%
single
202
Phase to neutral voltage, thd
%
single
204
Phase to neutral voltage, thd
%
single
206
Phase to phase voltage, thd
%
single
208
Phase to phase voltage, thd
%
single
210
Phase to phase voltage, thd
%
single
212
Phase current, thd
%
single
214
Phase current, thd
%
single
216
Phase current, thd
%
single
218
Frequency of u1n
Hz
single
220
Phase to neutral voltage, rms amplitude
V
single
222
Phase to neutral voltage, rms amplitude
V
single
224
Phase to neutral voltage, rms amplitude
V
single
226
Phase to phase voltage, rms amplitude
V
single
228
Phase to phase voltage, rms amplitude
V
single
230
Phase to phase voltage, rms amplitude
V
single
232
Phase current, rms amplitude
A
single
234
Phase current, rms amplitude
A
single
236
Phase current, rms amplitude
A
single
238
Neutral current, rms amplitude
A
single
240
Phase active power ( imp/ exp)
W
single
242
Phase active power ( imp/ exp)
W
single
244
Phase active power ( imp/ exp)
W
single
246
Phase reactive power ( imp/ exp)
var
single
248
Phase reactive power ( imp/ exp)
var
single
250
Phase reactive power ( imp/ exp)
var
single
252
Phase apparent power
VA
single
254
Phase apparent power
VA
single
256
Phase apparent power
VA
single
258
Phase power factor ( imp/ exp)
-
single
260
Phase power factor ( imp/ exp)
-
single
262
Phase power factor ( imp/ exp)
-
single
264
Phase to neutral voltage, mean thd
%
single
266
Phase to phase voltage, mean thd
%
single
268
Phase current, mean thd
%
single
270
Phase to neutral voltage, mean rms amplitude
V
single
272
Phase to phase voltage, mean rms amplitude
V
single
274
Three phase current, rms amplitude
A
single
276
Total active power ( imp/ exp)
W
single
278
Total reactive power ( imp/ exp)
var
single
280
Total apparent power
VA
single
282
Total power factor ( imp/ exp)
-
single
332
Phase current, rms amplitude, avg
A
single
334
Phase current, rms amplitude, avg
A
single
336
Phase current, rms amplitude, avg
A
single
344
Total imported active power, avg
W
single
346
Total imported inductive power, avg
var
single
348
Total imported capacitive power, avg
var
single
350
Total imported apparent power, avg
VA
single
352
Total exported active power, avg
W
single
There are more MODBUS items for this device. Please download the program to discover all registers.
Electrex (Flash 96) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
200
Phase to neutral voltage, thd
%
single
202
Phase to neutral voltage, thd
%
single
204
Phase to neutral voltage, thd
%
single
206
Line current, thd
%
single
208
Line current, thd
%
single
210
Line current, thd
%
single
212
Voltage input frequency
Hz
single
214
Phase to neutral voltage, rms amplitude
V
single
216
Phase to neutral voltage, rms amplitude
V
single
218
Phase to neutral voltage, rms amplitude
V
single
220
Phase to phase voltage, rms amplitude
V
single
222
Phase to phase voltage, rms amplitude
V
single
224
Phase to phase voltage, rms amplitude
V
single
226
Line current, rms amplitude
A
single
228
Line current, rms amplitude
A
single
230
Line current, rms amplitude
A
single
232
Neutral current, rms amplitude
A
single
234
Phase active power (+/)
W
single
236
Phase active power (+/)
W
single
238
Phase active power (+/)
W
single
240
Phase reactive power (+/)
var
single
242
Phase reactive power (+/)
var
single
244
Phase reactive power (+/)
var
single
246
Phase apparent power
VA
single
248
Phase apparent power
VA
single
250
Phase apparent power
VA
single
252
Phase power factor (+/)
single
254
Phase power factor (+/)
single
256
Phase power factor (+/)
single
258
Phase voltage, mean thd
%
single
260
Line current, mean thd
%
single
262
Phase to neutral mean voltage, rms amplitude
V
single
264
Phase to phase mean voltage, rms amplitude
V
single
266
Three phase current, rms amplitude
A
single
268
Total active power (+/)
W
single
270
Total reactive power (+/)
var
single
272
Total apparent power
VA
single
274
Total power factor (+/)
single
276
Total import active power, avg
W
single
280
Total import capacitive power, avg
var
single
284
Total export active power, avg
W
single
288
Total export capacitive power, avg
var
single
292
Total import active power, md
W
single
296
Total import capacitive power, md
var
single
There are more MODBUS items for this device. Please download the program to discover all registers.
Electrex (Flash D) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
200
Phase to neutral voltage, thd
%
single
202
Phase to neutral voltage, thd
%
single
204
Phase to neutral voltage, thd
%
single
206
Line current, thd
%
single
208
Line current, thd
%
single
210
Line current, thd
%
single
212
Voltage input frequency
Hz
single
214
Phase to neutral voltage, rms amplitude
V
single
216
Phase to neutral voltage, rms amplitude
V
single
218
Phase to neutral voltage, rms amplitude
V
single
220
Phase to phase voltage, rms amplitude
V
single
222
Phase to phase voltage, rms amplitude
V
single
224
Phase to phase voltage, rms amplitude
V
single
226
Line current, rms amplitude
A
single
228
Line current, rms amplitude
A
single
230
Line current, rms amplitude
A
single
232
Neutral current, rms amplitude
A
single
234
Phase active power (+/)
W
single
236
Phase active power (+/)
W
single
238
Phase active power (+/)
W
single
240
Phase reactive power (+/)
var
single
242
Phase reactive power (+/)
var
single
244
Phase reactive power (+/)
var
single
246
Phase apparent power
VA
single
248
Phase apparent power
VA
single
250
Phase apparent power
VA
single
252
Phase power factor (+/)
single
254
Phase power factor (+/)
single
256
Phase power factor (+/)
single
258
Phase voltage, mean thd
%
single
260
Line current, mean thd
%
single
262
Phase to neutral mean voltage, rms amplitude
V
single
264
Phase to phase mean voltage, rms amplitude
V
single
266
Three phase current, rms amplitude
A
single
268
Total active power (+/)
W
single
270
Total reactive power (+/)
var
single
272
Total apparent power
VA
single
274
Total power factor (+/)
single
276
Total import active power, avg
W
single
280
Total import capacitive power, avg
var
single
284
Total export active power, avg
W
single
288
Total export capacitive power, avg
var
single
292
Total import active power, md
W
single
296
Total import capacitive power, md
var
single
There are more MODBUS items for this device. Please download the program to discover all registers.
Electrex (Mico) - Mapping
MODBUS offset
Description
Units
Data type
20
Active Energy (total)
double
23
Reactive Energy (total)
double
Electrex (Plus) - MODBUS Registers Map
MODBUS offset
Description
Units
Data type
20
Active Energy (total)
double
23
Reactive Energy (total)
double
Related MODBUS registers maps
Eaton IQ250-IQ260 Power Meter
Eastron (X96)
Electrex Kilo
Electro Industries (Shark 250)
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.