DNC and CNC setting for Fanuc 18T
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
In the 'SET' mode select manual input mode and set following parameters |
IO CHANNEL | 0 |
PUNCH CODE | 1 |
TV CHECK | 0 |
Please, select following mode Offset Setting | System | Parameter (setting) and set following parameters |
#0000 | 0000 0010 |
#0020 (IO Channel) | 0 (RS232) |
#0100 | 0 |
#0101 (NFD) | 1000 0001 |
#0102 (Device number) | 0 |
#0103 | 9 |
If you want you can change baud rate in the parameter #0103 to: |
Baud | Parameter value |
1200 | 8 |
2400 | 9 |
4800 | 10 |
9600 | 11 |
19200 | 12 |
Set the following parameters on the PC
Serial port tab
Machine name | Fanuc 18T |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 2 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | False |
Set DTR | False |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Fanuc 18IT
Fanuc 18M
Fanuc 21M
Fanuc 21TB
Fanuc 21T
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.