Burny 1400 - DNC settings

Set the following parameters on the machine

Check the special protocols option in 'DSPY 80-CONFIGURE'
COMMUNICATION ENHANCEMENT OPTIONON
Permanently set all communication parameters in 'SD50-SERIAL DEFN'
PROTCL2 (XON/XOFF)
PGM TYPE1 = (Standard Burny 3 word address program)
CHAR TYPE CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS
BAUD RATE2400

Set the following parameters on the PC

Serial port tab

Machine nameBurny 1400
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: EOF:000
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: P
Program starting characters in the file: No
Program ending characters in the file: No

Set the following parameters on the machine

Permanently set all communication parameters in 'SD50-SERIAL DEFN'
PROTOCOLPROTCL-6 = CLINK 1
PROGRAM TYPEPGM TYPE-1 = WADR
CHARACTER TYPECHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS
BAUD RATEBAUD RATE-7 = 9600

Set the following parameters on the PC

Serial port tab

Machine nameBurny 2.5 CLINK
Serial portCOM2 (or any free COM port)
Baud9600
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSFalse
Set RTSFalse
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeData reception
Format parametersProgram start: #0D#0A%%#0D#0A
Program end: #1A#0D#0A
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: P
Program starting characters in the file: No
Program ending characters in the file: No

Burny 3 - DNC settings

Set the following parameters on the machine

Check the special protocols option in 'DSPY 80-CONFIGURE'
COMMUNICATION ENHANCEMENT OPTIONOFF
Permanently set all communication parameters in 'SD50-SERIAL DEFN' (see the 'INSTALL' section in your machine user manual)
PROTCL2 (XON/XOFF)
PGM TYPE1 = (Standard Burny 3 word address program)
CHAR TYPE 5 (OP7D-ASCII, Odd parity, 7 data bits)
BAUD RATE2400

Set the following parameters on the PC

Serial port tab

Machine nameBurny 3
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityOdd
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSFalse
Set RTSTrue
Set DTRTrue
Software flowcontrolBoth
Xon char#14
Xoff char#12

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Brother - TC-32 A
Bridgeport - Boss 9
Cincinatti Milacron - Acramatic 850-SX
Conquest CNC

If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.