DNC and CNC setting for Burny
These settings are for the DNC Precision software only. They may not work with other software.
Burny 1400 - DNC settings
Set the following parameters on the machine
Check the special protocols option in 'DSPY 80-CONFIGURE' |
COMMUNICATION ENHANCEMENT OPTION | ON |
Permanently set all communication parameters in 'SD50-SERIAL DEFN' |
PROTCL | 2 (XON/XOFF) |
PGM TYPE | 1 = (Standard Burny 3 word address program) |
CHAR TYPE | CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS |
BAUD RATE | 2400 |
Set the following parameters on the PC
Serial port tab
Machine name | Burny 1400 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | True |
Set RTS | True |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: EOF:000
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: P
Program starting characters in the file: No
Program ending characters in the file: No |
Burny 2.5 CLINK - NC settings
Set the following parameters on the machine
Permanently set all communication parameters in 'SD50-SERIAL DEFN' |
PROTOCOL | PROTCL-6 = CLINK 1 |
PROGRAM TYPE | PGM TYPE-1 = WADR |
CHARACTER TYPE | CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS |
BAUD RATE | BAUD RATE-7 = 9600 |
Set the following parameters on the PC
Serial port tab
Machine name | Burny 2.5 CLINK |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | False |
Set DTR | False |
Software flowcontrol | Both |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Data reception |
Format parameters | Program start: #0D#0A%%#0D#0A
Program end: #1A#0D#0A
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: P
Program starting characters in the file: No
Program ending characters in the file: No |
Burny 3 - DNC settings
Set the following parameters on the machine
Check the special protocols option in 'DSPY 80-CONFIGURE' |
COMMUNICATION ENHANCEMENT OPTION | OFF |
Permanently set all communication parameters in 'SD50-SERIAL DEFN' (see the 'INSTALL' section in your machine user manual) |
PROTCL | 2 (XON/XOFF) |
PGM TYPE | 1 = (Standard Burny 3 word address program) |
CHAR TYPE | 5 (OP7D-ASCII, Odd parity, 7 data bits) |
BAUD RATE | 2400 |
Set the following parameters on the PC
Serial port tab
Machine name | Burny 3 |
Serial port | COM2 (or any free COM port) |
Baud | 2400 |
Data bits | 7 |
Parity | Odd |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | False |
Require DSR | False |
Require CTS | False |
Set RTS | True |
Set DTR | True |
Software flowcontrol | Both |
Xon char | #14 |
Xoff char | #12 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %%
Program end: %%
Line start:
Line end: #0D#0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: Yes
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Brother - TC-32 A
Bridgeport - Boss 9
Cincinatti Milacron - Acramatic 850-SX
Conquest CNC
If you connected DNC Precision to another controller that is not on this list, please send us the information so we can add it to the list.