bg

DNC and CNC setting for Burny 1400

These settings are for the DNC Precision software only. They may not work with other software.

Set the following parameters on the machine

Check the special protocols option in 'DSPY 80-CONFIGURE'
COMMUNICATION ENHANCEMENT OPTIONON
Permanently set all communication parameters in 'SD50-SERIAL DEFN'
PROTCL2 (XON/XOFF)
PGM TYPE1 = (Standard Burny 3 word address program)
CHAR TYPE CHAR TYPE-3 = EP7D-ASCII, EVEN PARITY, 7 DATA BITS
BAUD RATE2400

Set the following parameters on the PC

Serial port tab

Machine nameBurny 1400
Serial portCOM2 (or any free COM port)
Baud2400
Data bits7
ParityEven
Stop bits1

Data flow control tab

Use DTRFalse
Use RTSFalse
Require DSRFalse
Require CTSTrue
Set RTSTrue
Set DTRFalse
Software flowcontrolBoth
Xon char#11
Xoff char#13

Data exchange format tab

Format modeUniform
Format parametersProgram start: %%
Program end: EOF:000
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: P
Program starting characters in the file: No
Program ending characters in the file: No

Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
 

Go to Index page
Bridgeport - Boss 9
Brother - TC-32 A
Burny 2.5 CLINK
Burny 3
Cincinatti Milacron - Acramatic 850-SX

If you have successfully connected DNC Precision with any other controller not in this list, we would appreciate your sending us the details to add to the list.

Note: We are not responsible and do not provide guarantee for any of these settings, that have been sent us by our customers.