DNC and CNC setting for Amada - Aries 245
These settings are for the DNC Precision software only. They may not work with other software.
Set the following parameters on the machine
Baud rate | 9600 |
Parity | Even |
Stop bits | 2 |
Data bits | 7 |
Punch code | 1 (ISO) |
Decimal input | 0 (YES) |
Set the following parameters on the PC
Serial port tab
Machine name | Amada - Aries 245 |
Serial port | COM2 (or any free COM port) |
Baud | 9600 |
Data bits | 7 |
Parity | Even |
Stop bits | 1 |
Data flow control tab
Use DTR | False |
Use RTS | True |
Require DSR | False |
Require CTS | True |
Set RTS | True |
Set DTR | True |
Software flowcontrol | None |
Xon char | #11 |
Xoff char | #13 |
Data exchange format tab
Format mode | Uniform |
Format parameters | Program start: %#0A
Program end: %
Line start:
Line end: #0A
Skip lines:
Ignore characters: No characters for remove
Remove blank lines: No
Program name prefix: O
Program starting characters in the file: No
Program ending characters in the file: No |
Null modem cable, without handshake
PC, 9pin, DB9M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 9pin, DB25M | CNC, 25pin, DB25
Null modem cable, without handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Null modem cable, with full handshake
PC, 25pin, DB25M | CNC, 25pin, DB25
Go to Index page
Acramatic - A2100
Allen Bradley 8600
Anilam Crusader II L
Anilam Crusader II M
Autocon
If you have successfully connected DNC Precision
with any other controller not in this list, we would appreciate your sending us the details to add to the list.
Note: We are not responsible and do not provide guarantee for any of these
settings, that have been sent us by our customers.